{"id":48145,"date":"2026-10-16T14:50:41","date_gmt":"2026-10-16T13:50:41","guid":{"rendered":"https:\/\/surespancovers.com\/se\/?p=48145"},"modified":"2026-10-16T14:50:41","modified_gmt":"2026-10-16T13:50:41","slug":"nar-kravs-brandgasventilation","status":"publish","type":"post","link":"https:\/\/surespancovers.com\/se\/nar-kravs-brandgasventilation\/","title":{"rendered":"N\u00e4r kr\u00e4vs brandgasventilation? Boverkets nya regler i BFS 2024:7"},"content":{"rendered":"<p>Brandgasventilation \u00e4r \u00f6ppningar i tak eller v\u00e4gg som sl\u00e4pper ut brandgaser och v\u00e4rme ur en byggnad n\u00e4r det brinner. F\u00f6r nya byggnader anger Boverkets f\u00f6reskrifter BFS 2024:7, i kraft sedan den 1 juli 2025, att brandgasventilation ska finnas i fyra slags utrymmen: utrymmen under mark, vissa f\u00f6rr\u00e5d i \u00f6versta planet, slutna garage och utrymmen med batterilager. Dessutom ska trapphus i byggnadsklass 1 kunna ventileras. Sj\u00e4lva produkten, brandgasventilatorn (i dagligt tal brandgaslucka), omfattas av den europeiska produktstandarden SS-EN 12101-2.<\/p>\n<p>Artikeln g\u00e4ller uppf\u00f6rande av nya byggnader i Sverige. Vid \u00e4ndring av byggnader g\u00e4ller s\u00e4rskilda best\u00e4mmelser i 9 och 10 kap. i samma f\u00f6reskrifter.<\/p>\n<h2>Vilka regler g\u00e4ller sedan BBR ersattes?<\/h2>\n<p>Brandskyddet i Boverkets nya byggregler finns i BFS 2024:7, Boverkets f\u00f6reskrifter och allm\u00e4nna r\u00e5d om s\u00e4kerhet i h\u00e4ndelse av brand i byggnader. F\u00f6reskrifterna tr\u00e4dde i kraft den 1 juli 2025, och kapitel 3 till 8 g\u00e4ller vid uppf\u00f6rande av nya byggnader. Boverkets byggregler, BBR, upph\u00e4vdes den 1 oktober 2026 genom BFS 2026:9. Enligt \u00f6verg\u00e5ngsbest\u00e4mmelserna i BFS 2026:9 f\u00e5r den upph\u00e4vda f\u00f6rfattningen \u00e4nd\u00e5 till\u00e4mpas p\u00e5 arbeten d\u00e4r ans\u00f6kan om bygglov eller anm\u00e4lan kommer in till kommunen f\u00f6re den 1 oktober 2027, under f\u00f6ruts\u00e4ttning att samtliga \u00e4ldre best\u00e4mmelser till\u00e4mpas. St\u00e4m av med byggnadsn\u00e4mnden vilket regelverk ert projekt pr\u00f6vas mot.<\/p>\n<h2>I vilka utrymmen kr\u00e4vs brandgasventilation?<\/h2>\n<p>Kravet st\u00e5r i 8 kap. 11 \u00a7 BFS 2024:7, i kapitlet om r\u00e4ddningspersonalens s\u00e4kerhet vid brand. Enligt 3 \u00a7 i samma kapitel ska byggnader vara utformade s\u00e5 att r\u00e4ddningspersonal kan ventilera ut brandgaser i den utstr\u00e4ckning som kr\u00e4vs f\u00f6r att genomf\u00f6ra r\u00e4ddningsinsatser med tillfredsst\u00e4llande s\u00e4kerhet. Brandgasventilation ska finnas i f\u00f6ljande utrymmen:<\/p>\n<ol>\n<li>Utrymmen under mark i brandceller st\u00f6rre \u00e4n 10\u00a0m\u00b2, f\u00f6rutom utrymningspassager, tilltr\u00e4desv\u00e4gar och liknande utrymmen.<\/li>\n<li>Brandceller st\u00f6rre \u00e4n 10\u00a0m\u00b2 som anv\u00e4nds som f\u00f6rr\u00e5d eller liknande i \u00f6versta planet i byggnader med fler \u00e4n fyra plan ovan mark.<\/li>\n<li>Slutna garage i brandceller st\u00f6rre \u00e4n 100\u00a0m\u00b2.<\/li>\n<li>Utrymmen med energilager i form av batterier med en kapacitet st\u00f6rre \u00e4n 20 kWh.<\/li>\n<\/ol>\n<h2>Hur stor ska \u00f6ppningen vara?<\/h2>\n<p>Samma paragraf anger den geometriska arean, allts\u00e5 \u00f6ppningens fysiska area, som en andel av nettoarean i de utrymmen som brandgasventilationen betj\u00e4nar:<\/p>\n<table class=\"mtr-table mtr-thead-th\">\n<thead>\n<tr>\n<th data-mtr-content=\"Brandcellen\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Brandcellen<\/div><\/th>\n<th data-mtr-content=\"Geometrisk area f\u00f6r \u00f6ppningarna, totalt\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Geometrisk area f\u00f6r \u00f6ppningarna, totalt<\/div><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-mtr-content=\"Brandcellen\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">skyddas inte med automatisk vattensprinkleranl\u00e4ggning<\/div><\/td>\n<td data-mtr-content=\"Geometrisk area f\u00f6r \u00f6ppningarna, totalt\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">minst 0,5 procent av nettoarean<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Brandcellen\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">skyddas med automatisk vattensprinkleranl\u00e4ggning<\/div><\/td>\n<td data-mtr-content=\"Geometrisk area f\u00f6r \u00f6ppningarna, totalt\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">minst 0,1 procent av nettoarean<\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Brandgasventilationen ska vara utformad som \u00f6ppningar och placerad s\u00e5 att utrymningspassager, tilltr\u00e4desv\u00e4gar eller andra verksamheter inte beh\u00f6ver anv\u00e4ndas f\u00f6r att ventilera ut brandgaserna, och s\u00e5 att tillr\u00e4cklig genomstr\u00f6mning av tilluft uppn\u00e5s. Brandgasventilation som betj\u00e4nar utrymmen under mark ska kunna man\u00f6vreras utifr\u00e5n eller via man\u00f6verdon vid angreppspunkt.<\/p>\n<p>Ett r\u00e4kneexempel: ett slutet garage utan sprinkler med 800\u00a0m\u00b2 nettoarea beh\u00f6ver \u00f6ppningar med sammanlagt minst 4\u00a0m\u00b2 geometrisk area. Skyddas brandcellen med automatisk vattensprinkleranl\u00e4ggning r\u00e4cker 0,8\u00a0m\u00b2. Hur arean f\u00f6rdelas p\u00e5 \u00f6ppningar och var tilluften tas in best\u00e4mmer brandskyddsprojekt\u00f6ren.<\/p>\n<h2>Vad g\u00e4ller f\u00f6r trapphus?<\/h2>\n<p>Byggnadsklass 1 omfattar enligt 2 kap. 6 \u00a7 byggnader i tre till tjugo plan ovan mark, f\u00f6rutom byggnader i tre plan som \u00e4r en- eller tv\u00e5bostadshus eller komplementbyggnader. I s\u00e5dana byggnader ska trapphus som utg\u00f6r tilltr\u00e4desv\u00e4g och trapphus som utg\u00f6r utrymningspassage kunna ventileras p\u00e5 n\u00e5got av tv\u00e5 s\u00e4tt (8 kap. 12 \u00a7):<\/p>\n<ul>\n<li>brandgasventilation i trapphusets topp med en geometrisk area p\u00e5 minst 1\u00a0m\u00b2, som aktiveras manuellt genom man\u00f6verdon vid trapphusets entr\u00e9, eller<\/li>\n<li>manuellt \u00f6ppningsbara f\u00f6nster eller liknande \u00f6ppningar i tilltr\u00e4desv\u00e4g utan r\u00e4ddningshiss, p\u00e5 minst vartannat plan samt det \u00f6versta planet.<\/li>\n<\/ul>\n<p>Kravet g\u00e4ller geometrisk area. Ett produktblad som bara anger aerodynamisk area svarar d\u00e4rf\u00f6r inte p\u00e5 fr\u00e5gan om \u00f6ppningen r\u00e4cker.<\/p>\n<h2>N\u00e4r g\u00e4ller inte de preciserade kraven?<\/h2>\n<p>Enligt 8 kap. 5 \u00a7 f\u00e5r kraven uppfyllas antingen genom de preciserade kraven i 6 till 15 \u00a7\u00a7 eller genom analytisk dimensionering. De preciserade kraven, och d\u00e4rmed procentsatserna ovan, f\u00e5r bara anv\u00e4ndas f\u00f6r verksamhetsklass 1 till 5 och byggnadsklass 1 till 3. Faller byggnaden utanf\u00f6r, eller v\u00e4ljer projekt\u00f6ren analytisk dimensionering, \u00e4r det den verifierade utformningen som best\u00e4mmer omfattningen av brandgasventilationen.<\/p>\n<h2>Vad kr\u00e4ver reglerna av sj\u00e4lva brandgasventilatorn?<\/h2>\n<p>BFS 2024:7 2 kap. 46 \u00a7 s\u00e4ger att brandgasventilation ska vara utformad med h\u00e4nsyn till sn\u00f6- och vindlaster samt de temperaturer som den kan f\u00f6rv\u00e4ntas uts\u00e4ttas f\u00f6r. Automatisk brandgasventilation ska dessutom ha tillr\u00e4ckligt snabb aktiveringstid och tillr\u00e4cklig kapacitet f\u00f6r att systemet med h\u00f6g tillf\u00f6rlitlighet ska kunna kontrollera brandgaser under avsedd tid. F\u00f6reskriften anger inga klasser i siffror. Den provade prestandan st\u00e5r i tillverkarens produktblad, och vilken prestanda platsen kr\u00e4ver best\u00e4mmer projekt\u00f6ren.<\/p>\n<p>Ett exempel: produktbladet f\u00f6r SRHP\/AOV fr\u00e5n 2018 anger sn\u00f6last SL500, vindlast WL1500, l\u00e5g omgivningstemperatur T (-15\u00b0) och v\u00e4rmet\u00e5lighet B300, med f\u00f6rbeh\u00e5llet att v\u00e4rdena g\u00e4ller SRHP\/AOV och att andra modeller kan avvika. J\u00e4mf\u00f6r klassen f\u00f6r l\u00e5g temperatur med de temperaturer som just er byggnadsplats kan f\u00f6rv\u00e4ntas ha, s\u00e5 som 46 \u00a7 kr\u00e4ver.<\/p>\n<h2>Geometrisk eller aerodynamisk area?<\/h2>\n<p>BFS 2024:7 r\u00e4knar med geometrisk area. Produktbladet f\u00f6r den m\u00e5ttanpassade brandgasventilatorn SRH-AOV redovisar b\u00e5da: geometrisk area utan vindavvisare och aerodynamisk area med vindavvisare enligt EN 12101-2.<\/p>\n<table class=\"mtr-table mtr-thead-th\">\n<thead>\n<tr>\n<th data-mtr-content=\"Modell\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Modell<\/div><\/th>\n<th data-mtr-content=\"Storlek (mm)\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Storlek (mm)<\/div><\/th>\n<th data-mtr-content=\"Geometrisk area, utan vindavvisare\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Geometrisk area, utan vindavvisare<\/div><\/th>\n<th data-mtr-content=\"Aerodynamisk area, med vindavvisare\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Aerodynamisk area, med vindavvisare<\/div><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-mtr-content=\"Modell\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">SRH-AOV\/125.125<\/div><\/td>\n<td data-mtr-content=\"Storlek (mm)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1250 x 1250<\/div><\/td>\n<td data-mtr-content=\"Geometrisk area, utan vindavvisare\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1,56\u00a0m\u00b2<\/div><\/td>\n<td data-mtr-content=\"Aerodynamisk area, med vindavvisare\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">0,93\u00a0m\u00b2<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Modell\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">SRH-AOV\/150.120<\/div><\/td>\n<td data-mtr-content=\"Storlek (mm)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1500 x 1200<\/div><\/td>\n<td data-mtr-content=\"Geometrisk area, utan vindavvisare\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1,80\u00a0m\u00b2<\/div><\/td>\n<td data-mtr-content=\"Aerodynamisk area, med vindavvisare\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1,12\u00a0m\u00b2<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Modell\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">SRH-AOV\/200.120<\/div><\/td>\n<td data-mtr-content=\"Storlek (mm)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">2000 x 1200<\/div><\/td>\n<td data-mtr-content=\"Geometrisk area, utan vindavvisare\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">2,40\u00a0m\u00b2<\/div><\/td>\n<td data-mtr-content=\"Aerodynamisk area, med vindavvisare\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1,58\u00a0m\u00b2<\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Enligt samma produktblad \u00e4r SRH-AOV CE-m\u00e4rkt enligt EN12101-2, finns i storlekar upp till 3000 x 1800\u00a0mm och kan monteras p\u00e5 tak med upp till 30\u00b0 lutning. CE-m\u00e4rkningen redovisar provad prestanda. Den visar inte att en viss \u00f6ppning uppfyller kraven i ett visst projekt.<\/p>\n<h2>Vilken brandgasventilator passar var?<\/h2>\n<ul>\n<li><a href=\"https:\/\/surespancovers.com\/se\/product\/brandgasventilator-med-takutgang\/\">Brandgasventilator med takutg\u00e5ng<\/a> (SRH-PAOV): brandgasventilation, daglig v\u00e4dring och tilltr\u00e4de till taket i samma enhet. Storlekar upp till 1260 x 1260\u00a0mm, CE-m\u00e4rkt enligt EN12101-2.<\/li>\n<li><a href=\"https:\/\/surespancovers.com\/se\/product\/exi-vent-taklucka\/\">Exi-Vent taklucka<\/a> (SV-EXI): en taklucka och en separat brandgasventilator, \u00e5tskilda av en regnr\u00e4nna p\u00e5 minst 150\u00a0mm. I produktbladets exempel kan enheterna man\u00f6vreras var f\u00f6r sig.<\/li>\n<li><a href=\"https:\/\/surespancovers.com\/se\/product\/glasad-brandgasventilator\/\">Glasad brandgasventilator<\/a> (SRHG-AOV): glasat lock som sl\u00e4pper in dagsljus, storlekar upp till 3000 x 1400\u00a0mm, CE-m\u00e4rkt enligt EN12101-2.<\/li>\n<li><a href=\"https:\/\/surespancovers.com\/se\/product\/mattanpassad-brandgasventilator\/\">M\u00e5ttanpassad brandgasventilator<\/a> (SRH-AOV): f\u00f6r stora \u00f6ppningar, se tabellen ovan.<\/li>\n<\/ul>\n<p>En vanlig taklucka \u00e4r ingen brandgasventilator. Produktbladet f\u00f6r standardtaklucka SRHP75 anger ingen provning enligt EN 12101-2. Beh\u00f6vs b\u00e5de tilltr\u00e4de och brandgasventilation i samma \u00f6ppning v\u00e4ljer ni en produkt som \u00e4r gjord f\u00f6r b\u00e5da. Hela sortimentet finns under <a href=\"https:\/\/surespancovers.com\/se\/product-category\/brandgasventilatorer\/\">Brandgasventilatorer<\/a>.<\/p>\n<h2>Vanliga fr\u00e5gor<\/h2>\n<h3>Kr\u00e4vs brandgasventilation i alla k\u00e4llare?<\/h3>\n<p>Nej. Enligt 8 kap. 11 \u00a7 BFS 2024:7 kr\u00e4vs det i utrymmen under mark i brandceller st\u00f6rre \u00e4n 10\u00a0m\u00b2, f\u00f6rutom utrymningspassager, tilltr\u00e4desv\u00e4gar och liknande utrymmen, och kravet h\u00f6r till de preciserade krav som f\u00e5r anv\u00e4ndas f\u00f6r verksamhetsklass 1 till 5 och byggnadsklass 1 till 3.<\/p>\n<h3>M\u00e5ste brandgasventilationen \u00f6ppna automatiskt?<\/h3>\n<p>Paragraferna 11 och 12 kr\u00e4ver att ventilationen kan man\u00f6vreras, i trapphus manuellt fr\u00e5n trapphusets entr\u00e9 och under mark utifr\u00e5n eller vid angreppspunkt. De kr\u00e4ver inte automatisk \u00f6ppning. V\u00e4ljs automatisk brandgasventilation g\u00e4ller kraven i 2 kap. 46 \u00a7 p\u00e5 aktiveringstid och kapacitet.<\/p>\n<h3>R\u00e4cker en brandgasventilator p\u00e5 1\u00a0m\u00b2 i trapphuset?<\/h3>\n<p>I byggnadsklass 1 \u00e4r en brandgasventilator i trapphusets topp med minst 1\u00a0m\u00b2 geometrisk area, som aktiveras manuellt vid trapphusets entr\u00e9, ett av de tv\u00e5 alternativen i 8 kap. 12 \u00a7. Kontrollera att produktbladet anger geometrisk area f\u00f6r den storlek ni v\u00e4ljer.<\/p>\n<h3>G\u00e4ller BBR fortfarande?<\/h3>\n<p>BBR upph\u00e4vdes den 1 oktober 2026. Enligt \u00f6verg\u00e5ngsbest\u00e4mmelserna i BFS 2026:9 f\u00e5r BBR till\u00e4mpas p\u00e5 arbeten d\u00e4r ans\u00f6kan om bygglov eller anm\u00e4lan kommer in f\u00f6re den 1 oktober 2027, om samtliga \u00e4ldre best\u00e4mmelser till\u00e4mpas.<\/p>\n<h3>Vilken standard g\u00e4ller f\u00f6r brandgasventilatorer?<\/h3>\n<p>Produktstandarden \u00e4r SS-EN 12101-2:2017, som enligt SIS \u00e4r g\u00e4llande. Surespans produktblad f\u00f6r SRH-PAOV, SRH-AOV, SRHG-AOV och SV-EXI anger att produkterna \u00e4r CE-m\u00e4rkta enligt EN12101-2. Produktblad och ritningar finns i <a href=\"https:\/\/surespancovers.com\/se\/dokumentationscenter\/dokumentation-brandgasventilatorer\/\">Dokumentation f\u00f6r brandgasventilatorer<\/a>.<\/p>\n<p>Har ni ett projekt d\u00e4r brandgasventilation ska dimensioneras, <a href=\"https:\/\/surespancovers.com\/se\/kontakt\/\">kontakta oss<\/a> med ritningar och brandskyddsbeskrivning s\u00e5 \u00e5terkommer vi med ett f\u00f6rslag.<\/p>\n<h2>K\u00e4llor<\/h2>\n<ul>\n<li>Produktblad &#8221;Bespoke Smoke Vent&#8221;, SRH-AOV, REV 1.0, juni 2022: <a href=\"https:\/\/surespancovers.com\/se\/product\/mattanpassad-brandgasventilator\/\">M\u00e5ttanpassad brandgasventilator<\/a><\/li>\n<li>Produktblad &#8221;Smoke Vent with Access&#8221;, SRH-PAOV, REV 1.0, juni 2022: <a href=\"https:\/\/surespancovers.com\/se\/product\/brandgasventilator-med-takutgang\/\">Brandgasventilator med takutg\u00e5ng<\/a><\/li>\n<li>Produktblad &#8221;SRHPAOV Solid Insulated Lid&#8221;, SRHP\/AOV, RF REV 3, maj 2018: <a href=\"https:\/\/surespancovers.com\/se\/product\/brandgasventilator-med-takutgang\/\">Brandgasventilator med takutg\u00e5ng<\/a><\/li>\n<li>Produktblad &#8221;Exi-Vent Roof Hatch&#8221;, SV-EXI, REV 1.0, juni 2022: <a href=\"https:\/\/surespancovers.com\/se\/product\/exi-vent-taklucka\/\">Exi-Vent taklucka<\/a><\/li>\n<li>Produktblad &#8221;Glazed Smoke Vent&#8221;, SRHG-AOV, REV 1.0, juni 2022: <a href=\"https:\/\/surespancovers.com\/se\/product\/glasad-brandgasventilator\/\">Glasad brandgasventilator<\/a><\/li>\n<li>Produktblad &#8221;Standard Roof Hatch&#8221;, SRHP75, maj 2021: <a href=\"https:\/\/surespancovers.com\/se\/product\/standardtaklucka\/\">Standardtaklucka<\/a><\/li>\n<li>BFS 2024:7, Boverkets f\u00f6reskrifter och allm\u00e4nna r\u00e5d om s\u00e4kerhet i h\u00e4ndelse av brand i byggnader, 1 kap. 2 \u00a7, 2 kap. 6 \u00a7 och 46 \u00a7, 8 kap. 3, 5, 11 och 12 \u00a7\u00a7: <a href=\"https:\/\/rinfo.boverket.se\/BFS2024-7\/pdf\/BFS2024-7.pdf\" target=\"_blank\" rel=\"noopener\">Boverket<\/a><\/li>\n<li>BFS 2026:9, Boverkets f\u00f6reskrifter om energihush\u00e5llning och v\u00e4rmeisolering i byggnader, \u00f6verg\u00e5ngsbest\u00e4mmelser: <a href=\"https:\/\/rinfo.boverket.se\/BFS2026-9\/pdf\/BFS2026-9.pdf\" target=\"_blank\" rel=\"noopener\">Boverket<\/a><\/li>\n<li>SS-EN 12101-2:2017, Smoke and heat control systems, Part 2: Natural smoke and heat exhaust ventilators: <a href=\"https:\/\/www.sis.se\/en\/produkter\/environment-health-protection-safety\/protection-against-fire\/fire-protection\/ssen1210122017\/\" target=\"_blank\" rel=\"noopener\">SIS<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Vilka utrymmen som ska ha brandgasventilation enligt Boverkets nya byggregler, hur stor \u00f6ppningen ska vara och vad det betyder f\u00f6r valet av brandgasventilator.<\/p>\n","protected":false},"author":6,"featured_media":35944,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_ayudawp_aiss_exclude":false,"_ayudawp_aiss_exclude_summary":false,"_ayudawp_aiss_summary":"","_ayudawp_aiss_summary_provider":"","_ayudawp_aiss_summary_hash":"","footnotes":""},"categories":[525],"tags":[],"country":[],"product-supplied":[],"class_list":["post-48145","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles"],"acf":[],"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/posts\/48145","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/comments?post=48145"}],"version-history":[{"count":0,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/posts\/48145\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/media\/35944"}],"wp:attachment":[{"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/media?parent=48145"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/categories?post=48145"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/tags?post=48145"},{"taxonomy":"country","embeddable":true,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/country?post=48145"},{"taxonomy":"product-supplied","embeddable":true,"href":"https:\/\/surespancovers.com\/se\/wp-json\/wp\/v2\/product-supplied?post=48145"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}