Surespan designs and manufactures thermally broken roof access hatches, smoke vents with access CE marked to EN 12101-2, and fire-rated and load-rated floor access covers for data centre and colocation projects in the UK and worldwide. From roof plant decks and chiller yards to switchgear pits, cable trenches and riser zones, we supply secure maintenance access with the drawings, BIM content and technical submittals your consultant needs to approve it.
Data centres need access products that protect the roof envelope, keep fire compartments intact and stay under the operator’s control. Surespan manufactures roof access hatches, AOV smoke vents, floor access covers and fixed access ladders for hyperscale, colocation and enterprise data centres. We work with main contractors, M&E consultants, roofing contractors and operators’ engineering teams on roof plant access, smoke ventilation, switchgear and cable pit covers and riser access, backed by drawings, BIM content and documented test data.
Gas spring assisted opening, hold-open stays, anti-slip surfaces and fall-prevention options such as safety grids and handrails help maintenance teams reach chillers, condensers and roof plant safely during routine and reactive maintenance.
Electrically operated hatches and smoke vents can be supplied with control panels, battery back-up, key switches, push buttons and fire alarm inputs, with open/closed status available to the BMS. Our BMS-ready guide explains what to specify.
Roof hatches can be specified with padlockable handles or European deadlocks with key operation, floor covers with locking options, and fixed ladders with a padlockable guard that stops unauthorised climbing. Tell us the security requirement and we will confirm the right arrangement.
Where access passes through fire-separating construction, fire-rated roof hatches and fire-rated recessed, flush and heavy duty floor hatches offer fire resistance of up to 4 hours to BS EN 1634-1, depending on size and configuration.
We develop single, double and multi-leaf configurations for large plant openings, lids that sit flush with roof grating, and details for non-standard build-ups, supported by coordinated drawings, revision control, QA documentation and lead times confirmed against your programme.
Match each zone of a data centre to the Surespan products normally specified there. Performance figures are those published on each product page and datasheet. Confirm project-specific loading, fire rating and controls with our technical team.
Data centre zone | What the project needs | Surespan products |
|---|---|---|
Roof plant decks and chiller yards | Weathertight, thermally broken roof access for routine plant maintenance | Standard Roof Hatch (SRHP75) and Double Leaf Roof Hatch (SRHP/DL) for larger openings. Class A7 weathertightness, IPX6 and IP6X (UKAS tested). |
Roof-level smoke ventilation | Smoke ventilation and roof access from one roof opening | Smoke Vent with Access (SRHP-AOV), Exi-Vent Roof Hatch with independent access and smoke vent leaves, and Dome Smoke Vent (SDP-MD-50). CE marked to EN 12101-2. |
Fire-separated plant rooms and risers | Access through fire-rated roof or floor construction | Fire Rated Roof Hatch (SRHTB/FR) and fire-rated floor hatches. Up to 4 hours to BS EN 1634-1, depending on configuration. |
Switchgear pits, cable trenches and service voids | Flush, lockable floor access that matches the surrounding floor finish | |
Plant replacement routes and yards | Trafficable covers rated for the wheel or equipment load | Heavy Duty Floor Hatch (SEHDC), with loading confirmed per project. See our floor hatch loadings guide. |
Offices, corridors and support areas | Discreet pedestrian floor access | |
Ladder access to roof hatches | A safe route to the hatch and protection against unauthorised climbing | Fixed Vertical Ladders (SL) with an optional padlockable ladder guard |
Surespan provides the technical information consultants, building control and contractors need to approve and install access products on data centre projects. Our Resource Centre is organised for BIM-led workflows and formal submittals, so project teams can find the right datasheet, drawing or model quickly.
Access datasheets, performance summaries, load classifications, installation guidance, and supporting documentation commonly required on data centre projects, including thermally broken roof hatches, flush and recessed access covers, and smoke vents with access.
Download DWG details and BIM models for standard products and typical configurations. Files support efficient integration with roof build-ups, structural openings, access routes, and service zone coordination.
Most data centre packages combine thermally broken roof access hatches for plant maintenance, smoke vents with access or Exi-Vent roof hatches where roof-level smoke ventilation is required, fire-rated roof hatches where access passes through fire-separating construction, and recessed or flush floor access covers for switchgear pits, cable trenches and service voids. Fixed ladders with lockable ladder guards complete the access route. The specification guide on this page shows which product suits each zone.
Yes. Recessed floor hatches (HIAC) take the surrounding floor finish so the cover blends into the floor, flush floor hatches (SAC) provide a plain flush cover, and heavy duty covers (SEHDC) suit plant and vehicle routes. Covers can be lockable, fire rated and electrically operated. Send us the opening size, loading, fire rating and floor finish and we will recommend the right cover.
Data centre enquiries frequently require confirmation of a fixed delivery date to match access windows and programme milestones. As a guide from historic data centre orders, some items are supplied ex-stock (2 to 3 working days), standard manufactured products often fall in the 2 to 6 week range, and larger bespoke units can extend to 10 to 12 weeks. Once you share sizes, quantities and required controls, we will confirm an achievable programme-aligned lead time.
Yes, this is a common coordination request on data centre roofs. We typically need the grating specification (for example thickness and bearing detail) and the steel support strategy so the lid and frame are fabricated to suit and the hatch bears correctly. If you provide the grating and steelwork details early, we can coordinate the hatch interface and avoid site rework.
We supply the hatch assembly and provide installation guidance, but the supporting structure around the opening remains a key design coordination point. Contractors often ask whether additional steelwork is required to support the frame or to integrate with grating. If you share the structural opening, roof build-up and edge conditions, we will advise the typical builder’s work requirements and confirm fixing approach during drawings.
Certification and actuator configuration are frequent technical queries. Our smoke vents with access are CE marked to EN 12101-2, and where a CE-marked smoke ventilator is required the actuator arrangement must match the tested configuration that underpins compliance. If a concealed actuator detail is requested, we will confirm whether it can remain compliant, or recommend an alternative compliant configuration that meets the project’s approval requirements. For projects outside the UK, see our guide to smoke vent standards worldwide.
Control specification is a common request, particularly where access or smoke ventilation interfaces with site procedures. Control panels can be supplied with battery back-up, and key switches, push buttons and fire alarm inputs can be specified where controlled operation is required. Electrically operated units can provide open/closed status for the BMS through the controls contractor’s interface. Share the operational intent (access only, smoke control interface, BMS integration, local override) and we will recommend an appropriate control set. Our BMS-ready specification guide explains the options.
Roof hatches can be supplied with a padlockable external handle or European deadlocks with key operation, floor covers can be specified with locking options, and electrically operated units can use key switches so only authorised staff can open them. Fixed ladders can be fitted with a padlockable ladder guard. If your project specifies a tested security standard, tell us the standard and class and we will confirm what can be supplied.
Yes. Fire-rated versions of our recessed, flush and heavy duty floor hatches are available with fire resistance of up to 4 hours to BS EN 1634-1, depending on size and configuration. Share the required fire rating, loading and floor finish and we will confirm the right cover.
The SRHP75 and SRHP/DL roof hatches have a thermally broken composite lid and upstand, a Class A7 weathertightness rating, and UKAS-tested IPX6 water ingress and IP6X dust ingress results. Thermal performance depends on the product and insulation, so compare U-values like for like using each product’s datasheet. Our guide to U-values and thermal breaks explains how.
Yes. Data centre schemes often require formal submittals with clear revision control. We can provide coordinated drawings (PDF and DWG) and support information for consultant review, enabling technical submissions to move through approvals efficiently.
Yes. For Vantage Data Centre in Ireland we supplied custom Grade 316L stainless steel Exi-Vent units, CE marked to EN 12101-2, with access leaves opening to 85 degrees, smoke vent leaves opening to 140 degrees, a 210 mm central rain channel and a manual hand pump for operation during a power failure. Other data centre projects include Virtus LON14, Gyron, Kenley Micro Data Centre, Meta ODN3 and The Chess Building in Watford.