DATA CENTRES | ROOF & FLOOR ACCESS SYSTEMS

Roof hatches, smoke vents and floor access covers for data centres

Manufacturing since 1969

Your Technical Partner for Data Centre Access

Thermal and weather performance

The SRHP75 and SRHP/DL roof hatches combine a thermally broken composite lid and upstand with a Class A7 weathertightness rating and UKAS-tested IPX6 water ingress and IP6X dust ingress results, keeping roof openings over data halls and plant weathertight.

Safe maintenance access

Gas spring assisted opening, hold-open stays, anti-slip surfaces and fall-prevention options such as safety grids and handrails help maintenance teams reach chillers, condensers and roof plant safely during routine and reactive maintenance.

Controls, BMS and standby power

Electrically operated hatches and smoke vents can be supplied with control panels, battery back-up, key switches, push buttons and fire alarm inputs, with open/closed status available to the BMS. Our BMS-ready guide explains what to specify.

Locking and access control

Roof hatches can be specified with padlockable handles or European deadlocks with key operation, floor covers with locking options, and fixed ladders with a padlockable guard that stops unauthorised climbing. Tell us the security requirement and we will confirm the right arrangement.

Fire-rated roof and floor access

Where access passes through fire-separating construction, fire-rated roof hatches and fire-rated recessed, flush and heavy duty floor hatches offer fire resistance of up to 4 hours to BS EN 1634-1, depending on size and configuration.

Coordination, submittals and delivery

We develop single, double and multi-leaf configurations for large plant openings, lids that sit flush with roof grating, and details for non-standard build-ups, supported by coordinated drawings, revision control, QA documentation and lead times confirmed against your programme.

BSI Assurance Mark ISO 9001
BSI Assurance Mark ISO 14001

DATA CENTRE SPECIFICATION GUIDE

Which access product goes where on a data centre

Match each zone of a data centre to the Surespan products normally specified there. Performance figures are those published on each product page and datasheet. Confirm project-specific loading, fire rating and controls with our technical team.

Data centre zone
What the project needs
Surespan products
Roof plant decks and chiller yards
Weathertight, thermally broken roof access for routine plant maintenance
Standard Roof Hatch (SRHP75) and Double Leaf Roof Hatch (SRHP/DL) for larger openings. Class A7 weathertightness, IPX6 and IP6X (UKAS tested).
Roof-level smoke ventilation
Smoke ventilation and roof access from one roof opening
Smoke Vent with Access (SRHP-AOV), Exi-Vent Roof Hatch with independent access and smoke vent leaves, and Dome Smoke Vent (SDP-MD-50). CE marked to EN 12101-2.
Fire-separated plant rooms and risers
Access through fire-rated roof or floor construction
Fire Rated Roof Hatch (SRHTB/FR) and fire-rated floor hatches. Up to 4 hours to BS EN 1634-1, depending on configuration.
Switchgear pits, cable trenches and service voids
Flush, lockable floor access that matches the surrounding floor finish
Plant replacement routes and yards
Trafficable covers rated for the wheel or equipment load
Heavy Duty Floor Hatch (SEHDC), with loading confirmed per project. See our floor hatch loadings guide.
Offices, corridors and support areas
Discreet pedestrian floor access
Ladder access to roof hatches
A safe route to the hatch and protection against unauthorised climbing
Fixed Vertical Ladders (SL) with an optional padlockable ladder guard

DATA CENTRE PROJECT EXPERIENCE

Proven across data centre and critical infrastructure projects

TECHNICAL RESOURCES FOR DATA CENTRE PROJECTS

Specification support for data centres and colocation facilities

Find Surespan on specification platforms
AIA
AEC Daily
RIB SpecLink

DATA CENTRE SECTOR PRODUCTS

Access solutions commonly specified for data centre projects

DATA CENTRE PROJECT QUESTIONS

Frequently asked by architects & contractors