Surespan designs and manufactures thermally broken roof access hatches, fire-rated roof and floor access hatches, smoke vents with access CE marked to EN 12101-2 and fixed and retractable access ladders for schools, colleges and universities in the UK and worldwide. From teaching block roofs and roof plant to plant rooms, courtyards and service voids, we supply lockable access for authorised staff, with the drawings, BIM content and technical submittals your design team needs to approve it.
Education buildings need roof and floor access that is safe for maintenance teams, out of reach of pupils and students, and coordinated with the fire strategy and the roof build-up. Surespan manufactures roof access hatches, fire-rated roof hatches, AOV smoke vents, floor access hatches and fixed, companionway and retractable ladders for primary and secondary schools, academies, further education colleges and university campuses. We work with architects, main contractors, roofing contractors, M&E consultants and estates teams on new-build and refurbishment projects, backed by drawings, BIM content and documented test data.
The SRHP75 roof hatch combines a thermally broken composite lid and upstand with a Class A7 weathertightness rating and UKAS-tested IPX6 water ingress and IP6X dust ingress results, so roof access over classrooms, halls and plant does not compromise the roof envelope. On existing buildings, the Retrofit Roof Hatch is designed to upgrade an existing opening with minimal disruption.
Roof hatches can be specified with a padlockable external handle (LO4) or European deadlocks with key operation (LO6 and LO7), floor hatches with locking options, and fixed ladders with a padlockable ladder guard that stops unauthorised climbing. Tell us the school or campus access and safeguarding requirements and we will confirm the right arrangement.
Roof hatches open with gas spring assistance, and options at the hatch include SureGuard hatch railing, a handhold and a ladder up post. Fixed vertical ladders with safety cages, companionway ladders and ZIP retractable ladders, which store away when not in use, complete the access route.
Where the fire strategy calls for smoke ventilation at roof level, the Smoke Vent with Access (SRHP-AOV) and the Exi-Vent Roof Hatch, whose access and smoke vent leaves operate independently, are CE marked to EN 12101-2. Control panels, battery back-up, key switches, push buttons and fire alarm inputs can be specified, with open/closed status available to the BMS. Our AOV controls guide explains the options.
Where access passes through fire-separating construction, the Fire Rated Roof Hatch (SRHTB/FR) and fire-rated recessed and flush floor hatches offer fire resistance of up to 4 hours to BS EN 1634-1, depending on size and configuration. At Killeen Elementary School in Texas, the fire-rated roof hatches were tested for 4-hour fire resistance to EN 1634-1:2014.
Recessed floor hatches (HIAC) take the surrounding floor finish as an infill, with a recess of up to 100 mm, so access to services sits flush in corridors, halls and courtyards. Flush and internal access hatches suit new or existing floors, and every project is supported by coordinated drawings, revision control and lead times confirmed against your programme.
Match each area of an education building to the Surespan products normally specified there. Performance figures are those published on each product page and datasheet. Confirm project-specific fire rating, locking and controls with our technical team.
Area of the building | What the project needs | Surespan products |
|---|---|---|
Teaching block, hall and roof plant access | Weathertight, thermally broken roof access for maintenance staff | Standard Roof Hatch (SRHP75). Class A7 weathertightness, IPX6 and IP6X (UKAS tested). Options include SureGuard hatch railing, a handhold and a ladder up post. |
Roof access from corridors, stores and plant rooms with limited space | A ladder that stores away when not in use | ZIP Retractable Ladders below the roof hatch, or Companionway Ladders (SHP) with handrails on both sides where there is more space. See our retractable ladder guide. |
Roof-level smoke ventilation | Smoke ventilation and roof access where the fire strategy requires it | Smoke Vent with Access (SRHP-AOV) and Exi-Vent Roof Hatch with independent access and smoke vent leaves. CE marked to EN 12101-2. |
Fire-separated plant rooms and risers | Access through fire-rated roof or floor construction | Fire Rated Roof Hatch (SRHTB/FR) and fire-rated floor hatches. Up to 4 hours to BS EN 1634-1, depending on configuration. |
Courtyards, halls and corridors over services | Floor access that matches the surrounding floor finish | Recessed Floor Hatch (HIAC) with an infill recess of up to 100 mm, or Flush Floor Hatch (SAC) with a chequer plate lid and optional SureGrip anti-slip coating. See how to specify recessed floor access covers. |
Refurbishment of existing buildings | Replacing roof hatches and adding floor access with minimal disruption | Retrofit Roof Hatch (SRHP/RF) for existing roof openings, and the Internal Access Hatch (IAC), which can be fitted after construction is complete. |
Ladder routes to roof hatches and plant | A safe climb and protection against unauthorised climbing | Fixed Vertical Ladders (SL) with a safety cage and an optional padlockable 2 m ladder guard |
Surespan provides the technical information architects, consultants, building control and contractors need to approve and install access products on school, college and university projects. The Resource Centre holds datasheets, fitting instructions, O&M manuals, PDF and DWG drawings and BIM models for our roof hatches, floor hatches, smoke vents and ladders, organised for coordination with roof build-ups, slab and screed depths, floor finishes and the project fire strategy.
Access datasheets, performance summaries, installation guidance and specification information for education projects, including thermally broken roof hatches, fire rated roof hatches and fire rated recessed floor access hatches used in high occupancy environments.
Download DWG details and BIM content to support Revit and CAD workflows, including typical hatch interfaces for warm roofs and internal floor build ups. Model and drawing resources are available for key ranges such as the SRHP75 and HIAC.
Typical education specifications combine thermally broken roof access hatches with a retractable, companionway or fixed ladder for roof plant maintenance, fire-rated roof hatches where access passes through fire-separating construction, smoke vents with access where the fire strategy needs roof-level smoke ventilation, and recessed, flush or internal floor access hatches for plant rooms, courtyards and service voids. The specification guide on this page shows which product suits each area.
The Fire Rated Roof Hatch (SRHTB/FR) and fire-rated versions of our recessed and flush floor hatches offer fire resistance of up to 4 hours to BS EN 1634-1, depending on size and configuration. At the Royal College of Music the recessed floor hatches have a 1-hour fire rating, and at Killeen Elementary School the roof hatches were tested for 4-hour fire resistance to EN 1634-1:2014. Tell us the rating the fire strategy requires for each opening and we will confirm the right product.
Roof and floor access on education sites is normally specified for authorised staff only. Roof hatches can be supplied with a padlockable external handle (LO4) or European deadlocks with key operation (LO6 and LO7), floor hatches can be specified with locking options, and electrically operated units can use key switches. Fixed ladders can be fitted with a padlockable ladder guard at the base to stop unauthorised climbing, and retractable ladders store away when not in use. If the project specifies a tested security standard, tell us the standard and class and we will confirm what can be supplied.
A ZIP retractable ladder below the roof hatch stores away when not in use. ZIP ladders are made from die-cast aluminium alloy with non-slip treads and a counterbalance spring, are certified to EN 14975, and are available in models ZIP4 to ZIP7 for ceiling heights up to 3390 mm, with fire-rated options. Where there is more space, a companionway ladder gives a more stable climb. Our retractable ladder guide explains the measurements we need.
Yes. The Smoke Vent with Access (SRHP-AOV) combines roof access and smoke ventilation in one unit, CE marked to EN 12101-2. Where the access and smoke vent functions need to be separate, the Exi-Vent Roof Hatch has access and smoke vent leaves that operate independently. Control panels, battery back-up, key switches, push buttons and fire alarm inputs can be specified. Whether an opening forms part of the smoke control strategy is for the project fire engineer to confirm.
The SRHP75 roof hatch has a thermally broken composite lid and upstand, a Class A7 weathertightness rating, and UKAS-tested IPX6 water ingress and IP6X dust ingress results. Thermal performance depends on the product and its insulation, so compare U-values like for like using each product’s datasheet. Our guide to U-values and thermal breaks explains how.
Surespan roof hatches have an external upstand liner fitted as standard to take a variety of hot or cold applied weathering materials, and the upstand height should allow for the insulation and waterproofing build-up. Our guides to upstand height for roof hatches and fire-rated roof hatches for green roofs and solar panels explain the details, and typical drawings and fitting instructions are in the Resource Centre.
Yes. The Recessed Floor Hatch (HIAC) has a recessed lid designed to accommodate any type of infill, with a recess of up to 100 mm, so the surrounding floor finish can continue across the cover. Where a plain metal lid is preferred, the Flush Floor Hatch (SAC) has a chequer plate lid with an optional SureGrip anti-slip coating. Send us the opening size, floor build-up, loading and fire rating and we will recommend the right cover. See our guide to specifying recessed floor access covers.
Yes. The Retrofit Roof Hatch (SRHP/RF) is designed for renovation projects, to upgrade an existing roof opening with minimal disruption. It has a thermally broken lid and upstand and gas spring assisted opening to 85 degrees, with finishes to suit the building. Send us the existing opening size and roof build-up and we will confirm the right unit.
Yes. The Resource Centre holds datasheets, fitting instructions, O&M manuals, PDF and DWG drawings and BIM models for our roof hatches, floor hatches, smoke vents and ladders, to support specification and coordination on education projects.
Lead times vary with size, specification and certification requirements. Standard configurations are usually quicker to programme than bespoke or fire-rated units, and the final lead time is confirmed at quotation stage for each education project.
Yes. At the Royal College of Music we supplied three HIAC recessed floor hatches with a 1-hour fire rating, linked to the smoke vent system. For Yale University we made a bespoke 2.7 m x 4.5 m stainless steel flush floor hatch with hydraulic operation for the Wright Laboratory. At Killeen Elementary School in Texas we supplied five fire-rated roof hatches with integral guard railing, and at California State University, Northridge a custom roof hatch with a retractable ladder and ceiling access panel.
Adding {{itemName}} to cart
Added {{itemName}} to cart