Surespan designs and manufactures thermally broken roof access hatches, smoke vents with access CE marked to EN 12101-2, and fire-rated and trafficable floor access hatches for stadiums, arenas, theatres and leisure venues in the UK and worldwide. From roof plant, lighting and services access to concourse floors, service yards and fire-separated plant rooms, we supply safe, controlled maintenance access with the drawings, BIM content and technical submittals your design team needs to approve it.
Stadiums, arenas and leisure venues need access products that keep the roof weathertight, keep fire compartments intact and keep maintenance access under the venue’s control. Surespan manufactures roof access hatches, AOV smoke vents, floor access hatches and fixed access ladders for sports stadiums, indoor arenas, ice rinks, theatres and leisure centres. We work with architects, main contractors, M&E consultants, fire engineers and venue facilities teams on roof plant and lighting access, roof-level smoke ventilation, concourse and back-of-house floor access, and fire-rated access through compartment lines, backed by drawings, BIM content and documented test data.
Gas spring assisted opening, hold-open stays and the SureGuard guardrail with a self-closing gate help maintenance teams reach plant, lighting and roof systems safely, as on the roof hatches supplied for Aston Villa’s Warehouse at Villa Park. Floor hatches can add safety grids, retractable handholds and pressure sensitive edges on electric units.
Large roof hatches can be electrically operated with synchronised 24V DC actuators and battery back-up, as at Education City Stadium, and smoke vents with access CE marked to EN 12101-2 combine roof access with smoke ventilation. Controls include control panels, key switches, push buttons and fire alarm inputs, with open/closed status to the BMS. Our BMS-ready guide explains what to specify.
Where access passes through fire-separating construction, fire-rated roof hatches and fire-rated recessed, flush and heavy duty floor hatches offer fire resistance of up to 4 hours to BS EN 1634-1, depending on size and configuration. At The Whiteley in London we supplied FR120 double-leaf flush floor hatches, with an independent expert judgement report for sizes beyond the tested range.
Where a hinged lid is not suitable, the SLHP sliding roof hatch uses a lift-and-slide lid, as supplied for Lusail Stadium and Ferrari World. Double leaf roof hatches and hydraulically or electrically operated double-leaf floor hatches cover large plant and equipment openings, such as the 4267 x 1768 mm floor covers at SoFi Stadium.
Roof hatches can be specified with padlockable handles or European deadlocks, floor hatches with locking options and fixed ladders with a padlockable guard. We issue general arrangement drawings for approval before manufacture, with schedules, revision control and documented QA for consultant review and project handover.
Match each zone of a stadium, arena, theatre or leisure venue to the Surespan products normally specified there. Performance figures are those published on each product page and datasheet, and project examples link to the case study. Confirm project-specific loading, fire rating and controls with our technical team.
Venue zone | What the project needs | Surespan products |
|---|---|---|
Roof plant, lighting and services access | Weathertight, thermally broken roof access with edge protection for routine maintenance | Standard Roof Hatch (SRHP75) and Double Leaf Roof Hatch (SRHP/DL). Class A7 weathertightness, IPX6 and IP6X (UKAS tested). SureGuard guardrail with a self-closing gate, as at Aston Villa, The Warehouse. |
Large roof openings and motorised access | Access where a hinged lid is not suitable, or where large lids must open electrically | Sliding Roof Hatch (SLHP) with a lift-and-slide lid, as at Lusail Stadium and Ferrari World. Electrically operated hatches with synchronised 24V DC actuators, as at Al Thumama and Education City stadiums. |
Roof-level smoke ventilation | Smoke ventilation and roof access from one roof opening | Smoke Vent with Access (SRHP-AOV), Exi-Vent Roof Hatch with independent access and smoke vent leaves, and Dome Smoke Vent (SDP-MD-50). CE marked to EN 12101-2. Combined access and smoke vent units were supplied for Al Janoub Stadium. |
Fire-separated plant rooms, risers and compartment lines | Access through fire-rated roof or floor construction | Fire Rated Roof Hatch (SRHTB/FR) and fire-rated floor hatches. Up to 4 hours to BS EN 1634-1, depending on size and configuration. FR120 floor hatches at The Whiteley. |
Concourses, foyers and public circulation | Floor access that sits flush and takes the surrounding floor finish | Recessed Floor Hatch (HIAC) with a recessed lid for the floor infill, or Flush Floor Hatch (SAC) where a metal lid suits. See how to specify recessed floor access covers. |
Service yards, loading areas and ice resurfacing routes | Trafficable covers rated for the wheel or equipment load | Heavy Duty Floor Hatch (SEHDC), with loading confirmed per project. At Mälarhöjdens ice hockey arena a Grade 316L stainless steel floor hatch was load tested to 35 kN for ice resurfacing machines. See our floor hatch loadings guide. |
Large plant and equipment openings in floors | Wide double-leaf floor access with powered operation | |
Back-of-house, offices and corridors | Discreet pedestrian floor access | |
Ladder access to roof hatches | A safe route to the hatch and protection against unauthorised climbing | Fixed Vertical Ladders (SL) with an optional padlockable ladder guard |
Surespan provides the technical information architects, consultants, building control and contractors need to approve and install access products on stadium, arena and leisure projects. The Resource Centre holds datasheets, fitting instructions, O&M manuals and CAD and BIM content, organised so project teams can coordinate each hatch with the roof build-up, slab and screed depths, concourse finishes and the fire strategy.
Datasheets, fitting instructions, O&M manuals and submittal drawings for each product on this page, including fire-rated roof hatches, fire-rated recessed floor hatches and heavy duty floor hatches for service and vehicle areas.
Download DWG details and BIM content to support Revit and CAD workflows. Each product page lists its downloads, from PDF and DWG submittal drawings to BIM models where available, for ranges such as the SRHP75 roof hatch and the HIAC recessed floor hatch.
Most venue packages combine thermally broken roof access hatches for plant, lighting and roof maintenance, sliding roof hatches where a hinged lid is not suitable, smoke vents with access or Exi-Vent roof hatches where roof-level smoke ventilation is required, fire-rated roof hatches and fire-rated floor hatches on compartment lines, and recessed or heavy duty floor access hatches for concourses, service yards and plant areas. Fixed ladders with lockable ladder guards complete the access route. The specification guide on this page shows which product suits each zone.
Fire-rated roof hatches (SRHTB/FR) and fire-rated recessed, flush and heavy duty floor hatches offer fire resistance of up to 4 hours to BS EN 1634-1, depending on size and configuration. The rating is chosen to suit the compartment line or protected route in the project fire strategy. For The Whiteley in London we supplied FR120 double-leaf flush floor hatches, with an independent expert judgement report covering sizes larger than the directly tested range.
Yes. The recessed floor hatch (HIAC) has a recessed lid designed to take an infill of the surrounding floor finish, so access points sit cleanly within concourse and foyer floors while staying serviceable for maintenance teams. Tell us the finish and its build-up depth and we will confirm the recess. Our guide to specifying recessed floor access covers lists what to send for a quote.
Floor hatches can be specified from pedestrian duty through to vehicular loading, and the rating is confirmed for each project against the wheel or equipment load. Heavy duty floor hatches (SEHDC) suit service yards and vehicle routes, and recessed floor hatches suit heavily trafficked concourse areas. At Mälarhöjdens ice hockey arena in Stockholm a stainless steel floor hatch was load tested to 35 kN for ice resurfacing machines. Our floor hatch loadings guide explains which load figures to give us.
Yes. Smoke vents with access (SRHP-AOV), Exi-Vent roof hatches and dome smoke vents (SDP-MD-50) are CE marked to EN 12101-2. The SRHP-AOV and Exi-Vent also provide roof access, and on the Exi-Vent the access and smoke vent leaves operate independently. For Al Janoub Stadium we supplied eight electrically operated roof access hatches that also act as smoke ventilators. Vent numbers and sizes follow the project smoke ventilation design, and our guide to sizing an AOV by free area explains the method.
Yes. For Al Thumama Stadium we supplied electrically operated roof hatches for a 4470 x 2000 mm opening, driven by synchronised 24V DC actuators, and for Education City Stadium eight 4000 x 1400 mm hatches with synchronised actuators and battery back-up. Electrically operated hatches and smoke vents can be supplied with control panels, battery back-up, key switches, push buttons and fire alarm inputs, with open/closed status available to the BMS through the controls contractor’s interface. Our BMS-ready specification guide explains the options.
A sliding roof hatch (SLHP) is specified where a hinged lid is not suitable. Its lift-and-slide lid is thermally broken as standard and can be electrically operated. For Lusail Stadium we supplied SLH/50 sliding hatches for 1900 x 1100 mm openings, with lids sliding on roof-mounted runners and SureGuard guardrails on all four sides, and for Ferrari World a motorised sliding hatch that gives maintenance crews access to the rollercoaster cars.
Roof hatches open with gas spring assistance and a hold-open stay, and can be fitted with the SureGuard guardrail, a permanent rail around the hatch with a self-closing gate, as supplied on the roof hatches at Aston Villa’s Warehouse at Villa Park. Floor hatches can add safety grids and retractable handholds, and fixed vertical ladders can have cages, walkthrough tops and a padlockable ladder guard. Our guide to handrail and guardrail load ratings explains the relevant standards.
Roof hatches can be supplied with a padlockable external handle (LO4) or European deadlocks with key operation (LO6 and LO7), floor hatches can be specified with locking options, and electrically operated units can use key switches so only authorised staff can open them. Fixed ladders can be fitted with a padlockable ladder guard. If your venue specifies a tested security standard, tell us the standard and class and we will confirm what can be supplied.
Yes. Datasheets, fitting instructions, PDF and DWG drawings and, where available, BIM models can be downloaded from each product page and from the Resource Centre. Surespan products are also listed on NBS Source for specification writers.
Lead times vary by size, specification and certification requirements. Standard configurations are typically quicker to programme than bespoke large-format or fire-rated units, and approval drawings are issued before manufacture. Final lead times are confirmed at quotation stage for each stadium, arena or leisure project.
Yes. Projects include Al Janoub Stadium, Education City Stadium, Al Thumama Stadium, Lusail Stadium and Khalifa International Stadium in Qatar, SoFi Stadium in Los Angeles, Mälarhöjdens ice hockey arena in Stockholm, The Warehouse at Villa Park for Aston Villa, Ferrari World in Abu Dhabi and The Whiteley in London. Each case study lists the products and sizes supplied.
Adding {{itemName}} to cart
Added {{itemName}} to cart