HEALTHCARE SECTOR | HOSPITALS, MEDICAL CENTERS AND CLINICS

Roof hatches, smoke vents and fire-rated floor hatches for hospitals and medical centers

Manufacturing since 1969

Your Technical Partner for Healthcare Access

Fire-rated roof and floor access

Where access passes through fire-rated construction, the Fire Rated Roof Hatch (SRHTB/FR) and fire-rated recessed, flush and heavy duty floor hatches offer fire resistance of up to 4 hours (240 minutes), supported by documented European fire-test data, depending on size and configuration.

Smoke ventilation with roof access

The Smoke Vent with Access (SRHP-AOV) combines rooftop access and smoke ventilation in one assembly, with 24V actuation supported by documented EN 12101-2 test data and a 24V control box with smoke detector, ventilation switch and fire switch. With the Exi-Vent Roof Hatch, the smoke vent and the roof access hatch can be sized independently.

Thermal and weather performance

The SRHP75 and SRHP/DL roof hatches have a thermally broken lid and upstand as standard and are backed by published third-party water-resistance, weather-sealing and dust-resistance test data, helping keep roof openings over clinical areas and mechanical rooms weathertight.

Locking and staff-only access

Roof hatches can be specified with a padlockable exterior handle (LO4) or European deadlocks with keyed operation (LO6 and LO7), electrically operated floor hatches with key switches, and fixed ladders with a padlockable access control guard, so roofs and mechanical spaces stay restricted to authorized facilities staff. Tell us the security requirement and we will confirm the right arrangement.

Access for medical and mechanical equipment

Sliding and double leaf roof hatches provide large clear openings for equipment. For Northwell Health in New York we supplied three custom sliding roof hatches, each with a 9 ft x 9 ft (2743 x 2743 mm) structural opening and a 230V geared motor, so large medical equipment can be installed and removed through the roof.

Submittals, approvals and delivery

Hospital projects run on submittals. We supply submittal drawings in PDF and DWG, BIM models, O&M manuals and QA documentation with consistent revision control, develop project-specific configurations for structural interfaces, finishes and fire strategy, and confirm lead times against your construction schedule.

BSI Assurance Mark ISO 9001
BSI Assurance Mark ISO 14001

HEALTHCARE SPECIFICATION GUIDE

Which access product goes where in a hospital

Match each area of a hospital or medical center to the Surespan products normally specified there. Performance information is as published on each product page and datasheet. Confirm project-specific fire rating, loading and controls with our technical team.

Hospital area
What the project needs
Surespan products
Rooftop equipment and maintenance routes
Weathertight, thermally broken roof access for routine maintenance
Standard Roof Hatch (SRHP75) and Double Leaf Roof Hatch (SRHP/DL) for larger openings, backed by published third-party water-resistance, weather-sealing and dust-resistance test data.
Roof-level smoke ventilation
Smoke ventilation and roof access from one roof opening
Smoke Vent with Access (SRHP-AOV), with documented EN 12101-2 test data, and Exi-Vent Roof Hatch, with the smoke vent and access hatch sized independently. See Ulster Hospital.
Equipment replacement routes
Large clear roof openings for medical and mechanical equipment
Fire-rated mechanical rooms, shafts and floors
Access through fire-rated roof or floor construction
Fire Rated Roof Hatch (SRHTB/FR) and fire-rated Recessed (HIAC) and Flush (SAC) floor hatches. Fire resistance up to 4 hours, supported by documented European fire-test data, depending on size and configuration. See The O’Quinn Medical Tower.
Service spaces and corridors
Discreet, lockable floor access that matches the floor finish
Recessed Floor Hatch (HIAC) for tile, screed, stone or concrete infills, and Internal Access Hatch (IAC) for pedestrian areas
Mechanical rooms with limited space
Ladder access that folds away when not in use
ZIP Retractable Ladders and ZIP8 Retractable Ladders, available in 30-minute or 90-minute fire-rated versions. See Ulster Hospital.
Ladder access to roof hatches
A safe route to the hatch and protection against unauthorized climbing
Fixed Vertical Ladders (SL) with an optional padlockable access control guard

HEALTHCARE PROJECT EXPERIENCE

Proven across hospitals and care facilities

TECHNICAL RESOURCES FOR HEALTHCARE PROJECTS

Specification support for hospitals and care facilities

Find Surespan on specification platforms
AIA
AEC Daily
RIB SpecLink

HEALTHCARE SECTOR PRODUCTS

Access solutions commonly specified for healthcare projects

HEALTHCARE PROJECT QUESTIONS

Frequently asked by architects & contractors

Explore
Drag