{"id":50041,"date":"2026-06-15T12:50:17","date_gmt":"2026-06-15T11:50:17","guid":{"rendered":"https:\/\/surespancovers.com\/us\/polyiso-or-mineral-wool-roof-hatch\/"},"modified":"2026-06-15T12:50:17","modified_gmt":"2026-06-15T11:50:17","slug":"polyiso-or-mineral-wool-roof-hatch","status":"publish","type":"post","link":"https:\/\/surespancovers.com\/us\/polyiso-or-mineral-wool-roof-hatch\/","title":{"rendered":"Polyiso or Mineral Wool in a Roof Hatch? Fire and Thermal Trade-offs"},"content":{"rendered":"<p>Polyiso (polyisocyanurate, PIR) insulates a roof hatch better for the same thickness, and mineral wool is non-combustible. That is the trade-off. On the same Surespan data sheet, 50\u00a0mm (2.0 in) of polyiso is given as 0.43\u00a0W\/m\u00b2K and 50\u00a0mm of non-combustible mineral wool as 0.63\u00a0W\/m\u00b2K, so the mineral wool lets more heat through. Both figures are the U-values of the insulation in the lid and curb, not of the complete hatch. On Surespan&#8217;s roof hatches, mineral wool is offered free of charge in place of polyiso.<\/p>\n<p>This guide is about the insulation inside the lid and curb of commercial roof hatches and smoke vents, not about roof insulation boards.<\/p>\n<h2>What is polyiso, and why do most roof hatches use it?<\/h2>\n<p>Polyiso is a rigid thermoset foam. Most roof hatch makers use it. Every roof hatch should be thermally broken as well as insulated, so that the aluminum frame does not conduct heat straight through the insulation. Surespan&#8217;s roof hatches are thermally broken and come with a curb liner as standard.<\/p>\n<p>Its drawback is fire. Polyiso can ignite, and if it does it can release the highly toxic gas hydrogen cyanide. Product literature that calls PIR fire retardant often refers to small scale tests that may not reflect every hazard.<\/p>\n<h2>What is mineral wool?<\/h2>\n<p>Mineral wool is made from natural, recyclable materials. Stone wool, one type, is made from volcanic rock. Surespan&#8217;s data sheets describe the mineral wool option as non-combustible. It lets more heat through at the same thickness, but it takes the foam out of the hatch.<\/p>\n<h2>How do the two compare on the data sheets?<\/h2>\n<table class=\"mtr-table mtr-thead-th\">\n<thead>\n<tr>\n<th data-mtr-content=\"\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\"><\/div><\/th>\n<th data-mtr-content=\"Polyiso (PIR)\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Polyiso (PIR)<\/div><\/th>\n<th data-mtr-content=\"Mineral wool\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Mineral wool<\/div><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-mtr-content=\"\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Insulation U-value at 50\u00a0mm (2.0 in), SRHP\/AOV sheet<\/div><\/td>\n<td data-mtr-content=\"Polyiso (PIR)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">0.43\u00a0W\/m\u00b2K<\/div><\/td>\n<td data-mtr-content=\"Mineral wool\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">0.63\u00a0W\/m\u00b2K<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Fire<\/div><\/td>\n<td data-mtr-content=\"Polyiso (PIR)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Can ignite, and can then release hydrogen cyanide<\/div><\/td>\n<td data-mtr-content=\"Mineral wool\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Described on the sheets as non-combustible<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Cost on Surespan hatches<\/div><\/td>\n<td data-mtr-content=\"Polyiso (PIR)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Standard<\/div><\/td>\n<td data-mtr-content=\"Mineral wool\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Free of charge option<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Choose it when<\/div><\/td>\n<td data-mtr-content=\"Polyiso (PIR)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">The energy model is tight and the fire strategy allows foam insulation<\/div><\/td>\n<td data-mtr-content=\"Mineral wool\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">The fire strategy or the client asks for non-combustible insulation<\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A lower U-value means less heat lost. The difference applies to a hatch, which is a small part of the roof. Ask for the whole-unit value of the hatch if your energy model needs one, because neither figure includes the frame and the cover.<\/p>\n<h2>Which Surespan hatches offer mineral wool?<\/h2>\n<ul>\n<li><a href=\"https:\/\/surespancovers.com\/us\/product\/sliding-roof-hatch\/\">Sliding roof hatch<\/a> (SLHP): 50mm polyiso to 0.43\u00a0W\/m\u00b2K as standard, non-combustible mineral wool free of charge.<\/li>\n<li><a href=\"https:\/\/surespancovers.com\/us\/product\/double-leaf-roof-hatch\/\">Double leaf roof hatch<\/a> (SRHP\/DL): 75mm (3.0 in) insulation, with non-combustible mineral wool free of charge.<\/li>\n<li><a href=\"https:\/\/surespancovers.com\/us\/product\/smoke-vent-with-access\/\">Smoke vent with access<\/a> (SRH-PAOV): 50mm polyiso to 0.43\u00a0W\/m\u00b2K as standard; the drawing shows polyisocyanurate or mineral wool, and mineral wool is a free of charge option.<\/li>\n<li><a href=\"https:\/\/surespancovers.com\/us\/product\/fire-rated-roof-hatch\/\">Fire rated roof hatch<\/a> (SRHTB\/FR): mineral wool insulation, 0.63\u00a0W\/m\u00b2K, with 50mm insulation in the curb.<\/li>\n<\/ul>\n<p>The fire rated roof hatch is a separate question from the insulation. Its sheet offers integrity for 60\/90\/120\/240 minutes, with the test standard printed on its drawings as EN1634-1:2014. The sheet gives integrity only: ask for the classification report, the fire direction and the tested size before you rely on it for a rated roof. Choosing mineral wool in an ordinary roof hatch does not make it a fire rated hatch.<\/p>\n<h2>What do US codes say about hatch insulation?<\/h2>\n<p>The fire and energy rules that apply to a roof hatch are set by the codes your jurisdiction has adopted and by the project&#8217;s fire strategy. Surespan&#8217;s sheets describe the mineral wool as non-combustible but do not cite a US test standard for that. If your specification calls for a non-combustible material under a named US test, ask for that evidence before you rely on it.<\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>Is mineral wool or polyiso better in a roof hatch?<\/h3>\n<p>Polyiso is better for heat loss: 0.43\u00a0W\/m\u00b2K against 0.63\u00a0W\/m\u00b2K at 50\u00a0mm on the same sheet. Mineral wool is better for fire, because it is non-combustible. Choose by which matters more on your project.<\/p>\n<h3>Does mineral wool cost more?<\/h3>\n<p>Not on Surespan&#8217;s hatches. The sheets list non-combustible mineral wool as a free of charge option.<\/p>\n<h3>Is the U-value on a roof hatch data sheet the U-value of the hatch?<\/h3>\n<p>No. The values on Surespan&#8217;s sheets are those of the insulation in the lid and curb. The whole hatch, with its frame, seals and cover, performs differently.<\/p>\n<h3>Does mineral wool make a roof hatch fire rated?<\/h3>\n<p>No. A fire rating comes from a fire test of the whole hatch. Use a hatch made and tested for it, such as the fire rated roof hatch.<\/p>\n<p>See the full <a href=\"https:\/\/surespancovers.com\/us\/product-category\/roof-hatches\/\">roof hatch range<\/a>, including the <a href=\"https:\/\/surespancovers.com\/us\/product\/standard-roof-hatch\/\">Standard Roof Hatch<\/a>. To ask about a specification, use the <a href=\"https:\/\/surespancovers.com\/us\/contact-us\/\">Surespan contact page<\/a>.<\/p>\n<h2>Sources<\/h2>\n<ul>\n<li>Surespan data sheet &#8220;Smoke Vent SRHPAOV&#8221; (SRHP\/AOV), RF REV 3, May 2018: 50\u00a0mm polyiso and mineral wool values. Range: <a href=\"https:\/\/surespancovers.com\/us\/product-category\/smoke-vents\/\">Smoke Vents<\/a>.<\/li>\n<li>Surespan data sheet &#8220;Thermally Broken SLHP (Telescopic) Sliding Hatch&#8221;, REV 2.0, March 2022: insulation, mineral wool option. Product page: <a href=\"https:\/\/surespancovers.com\/us\/product\/sliding-roof-hatch\/\">Sliding Roof Hatch<\/a>.<\/li>\n<li>Surespan data sheet &#8220;Double Door Roof Hatch SRHP\/DL&#8221;, July 2022: insulation thickness, mineral wool option. Product page: <a href=\"https:\/\/surespancovers.com\/us\/product\/double-leaf-roof-hatch\/\">Double Leaf Roof Hatch<\/a>.<\/li>\n<li>Surespan data sheet &#8220;Thermally Broken AOV&#8221; (SRH-PAOV), REV 1.0, June 2022: insulation, mineral wool option. Product page: <a href=\"https:\/\/surespancovers.com\/us\/product\/smoke-vent-with-access\/\">Smoke Vent with Access<\/a>.<\/li>\n<li>Surespan data sheet &#8220;Fire Rated Roof Hatch&#8221; (SRHTB\/FR), March 2026 (revision mark 06\/22): insulation, integrity durations, test standard. Product page: <a href=\"https:\/\/surespancovers.com\/us\/product\/fire-rated-roof-hatch\/\">Fire Rated Roof Hatch<\/a>.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Polyiso or mineral wool in a roof hatch lid and curb: the insulation values on the data sheets, the fire trade-off, and how to choose.<\/p>\n","protected":false},"author":2,"featured_media":30606,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_ayudawp_aiss_exclude":false,"_ayudawp_aiss_exclude_summary":false,"_ayudawp_aiss_summary":"Polyiso (polyisocyanurate, PIR) insulates a roof hatch better for the same thickness, and mineral wool is non-combustible. Fire rated roof hatch (SRHTB\/FR): mineral wool insulation, 0.63 W\/m\u00b2K, with 50mm insulation in the curb. Choosing mineral wool in an ordinary roof hatch does not make it a fire rated hatch.","_ayudawp_aiss_summary_provider":"extractive","_ayudawp_aiss_summary_hash":"2da32418e1a28fa60bacd897f34c54242f60f040","footnotes":""},"categories":[525],"tags":[],"country":[],"product-supplied":[],"class_list":["post-50041","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles"],"acf":[],"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts\/50041","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/comments?post=50041"}],"version-history":[{"count":0,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts\/50041\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/media\/30606"}],"wp:attachment":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/media?parent=50041"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/categories?post=50041"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/tags?post=50041"},{"taxonomy":"country","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/country?post=50041"},{"taxonomy":"product-supplied","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/product-supplied?post=50041"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}