{"id":50043,"date":"2026-01-22T13:07:35","date_gmt":"2026-01-22T12:07:35","guid":{"rendered":"https:\/\/surespancovers.com\/us\/roof-access-ladder-layouts\/"},"modified":"2026-01-22T13:07:35","modified_gmt":"2026-01-22T12:07:35","slug":"roof-access-ladder-layouts","status":"publish","type":"post","link":"https:\/\/surespancovers.com\/us\/roof-access-ladder-layouts\/","title":{"rendered":"Roof Access Ladders: Walk-Through, Parapet and Platform Layouts"},"content":{"rendered":"<p>A fixed roof access ladder reaches the roof in one of five layouts: up through a roof hatch from inside, over the roof edge as a walk-through ladder, beside the edge as a side-step ladder, over a parapet with a step-over platform, or in stages with landing platforms. Which one fits depends on where the climb starts, what is at the top edge and how high the roof is. For general industry workplaces the federal rules for each layout are in OSHA 29 CFR 1910.23, with fall protection for ladders over 24 feet (7.3\u00a0m) in 1910.28(b)(9).<\/p>\n<p>This guide compares the layouts and the OSHA paragraphs that shape each one. The general fixed ladder dimensions, such as rung spacing and clear width, apply to all of them and are not repeated here.<\/p>\n<h2>Roof access ladder layouts at a glance<\/h2>\n<table class=\"mtr-table mtr-thead-th\">\n<thead>\n<tr>\n<th data-mtr-content=\"Layout\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Layout<\/div><\/th>\n<th data-mtr-content=\"Where it fits\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Where it fits<\/div><\/th>\n<th data-mtr-content=\"OSHA paragraphs that shape it\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">OSHA paragraphs that shape it<\/div><\/th>\n<th data-mtr-content=\"Surespan SL arrangement\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Surespan SL arrangement<\/div><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-mtr-content=\"Layout\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Through a roof hatch<\/div><\/td>\n<td data-mtr-content=\"Where it fits\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Climb starts inside the top floor<\/div><\/td>\n<td data-mtr-content=\"OSHA paragraphs that shape it\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.23(d)(9)<\/div><\/td>\n<td data-mtr-content=\"Surespan SL arrangement\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">SL, with a hatch from the <a href=\"https:\/\/surespancovers.com\/us\/product-category\/roof-hatches\/\">roof hatch range<\/a><\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Layout\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Walk-through at the roof edge<\/div><\/td>\n<td data-mtr-content=\"Where it fits\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">External climb up a wall to an open roof edge<\/div><\/td>\n<td data-mtr-content=\"OSHA paragraphs that shape it\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.23(d)(4), (d)(5), (d)(12)(i)<\/div><\/td>\n<td data-mtr-content=\"Surespan SL arrangement\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">SL\/WT, SLC\/WT with cage<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Layout\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Side-step<\/div><\/td>\n<td data-mtr-content=\"Where it fits\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">The climber steps off sideways onto a roof or platform<\/div><\/td>\n<td data-mtr-content=\"OSHA paragraphs that shape it\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.23(d)(4), (d)(6), (d)(12)(ii)<\/div><\/td>\n<td data-mtr-content=\"Surespan SL arrangement\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Not a listed arrangement; ask<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Layout\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Parapet step-over<\/div><\/td>\n<td data-mtr-content=\"Where it fits\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Roof edge with a continuous parapet<\/div><\/td>\n<td data-mtr-content=\"OSHA paragraphs that shape it\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.23(d)(4)(ii)<\/div><\/td>\n<td data-mtr-content=\"Surespan SL arrangement\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">SL\/PS, SLC\/PS<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Layout\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Landing platforms<\/div><\/td>\n<td data-mtr-content=\"Where it fits\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">High climbs, or where the route changes direction<\/div><\/td>\n<td data-mtr-content=\"OSHA paragraphs that shape it\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.29(g)(4); 1910.28(b)(9)<\/div><\/td>\n<td data-mtr-content=\"Surespan SL arrangement\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Landing platforms as an option<\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>When is a ladder through a roof hatch the better choice?<\/h2>\n<p>Where the climb can start inside the building, the ladder is out of the weather, out of reach from the street, and usually short. When a fixed ladder terminates at a hatch, OSHA requires the hatch cover to open &#8220;with sufficient clearance to provide easy access to or from the ladder&#8221; and, if the hatch is counterbalanced, to open &#8220;at least 70 degrees from horizontal&#8221; (1910.23(d)(9)). Check the hatch opening and the headroom above the top rung together, and plan the guardrail at the hatch opening on the roof.<\/p>\n<h2>How does a walk-through ladder work at the roof edge?<\/h2>\n<p>A through ladder lets the climber step through the side rails at the top to reach the roof. OSHA sets three things at the top:<\/p>\n<ul>\n<li>the side rails extend at least 42 inches (1.1\u00a0m) above the top of the access level or landing platform served by the ladder (d)(4);<\/li>\n<li>the rungs are omitted from the extension, and the rails flare to give not less than 24 inches (61cm) and not more than 30 inches (76\u00a0cm) of clearance, or up to 36 inches (91\u00a0cm) where a ladder safety system is provided (d)(5);<\/li>\n<li>the step-across distance from the rung centerline to the nearest edge of the structure is not less than 7 inches (18\u00a0cm) and not more than 12 inches (30\u00a0cm) (d)(12)(i).<\/li>\n<\/ul>\n<p>Surespan&#8217;s fixed vertical ladder sheet lists this layout as the SL\/WT, standard ladder with walk through, and the SLC\/WT, with cage and walk through.<\/p>\n<h2>When does a side-step ladder make sense?<\/h2>\n<p>A side-step ladder is one the climber steps off sideways to reach the walking-working surface. It suits a ladder that runs up beside a platform or roof edge rather than onto it. OSHA requires the side rails, rungs and steps to be continuous in the extension (d)(6), the 42-inch extension above the access level (d)(4), and a step-across distance of not less than 15 inches (38\u00a0cm) and not more than 20 inches (51\u00a0cm) to the access points of the platform edge (d)(12)(ii). Surespan&#8217;s SL sheet does not list a side-step arrangement, so ask before you draw one.<\/p>\n<h2>How do parapet ladders work?<\/h2>\n<p>A parapet changes where the 42-inch extension is measured from. For parapet ladders, OSHA defines the access level as &#8220;the roof, if the parapet is cut to permit passage through the parapet&#8221; or &#8220;the top of the parapet, if the parapet is continuous.&#8221; With a continuous parapet, the rails therefore extend 42 inches above the parapet top, and the climber needs a safe way down onto the roof on the other side.<\/p>\n<p>That is the job of a step-over platform. Surespan&#8217;s sheet lists the SL\/PS and SLC\/PS, a standard ladder with walk through and parapet stepover platform, without and with a cage. Cutting the parapet for a walk-through is the alternative, and the access level is then the roof.<\/p>\n<h2>Where do landing platforms go?<\/h2>\n<p>Platforms used with fixed ladders must provide a horizontal surface of at least 24 inches by 30 inches (61\u00a0cm by 76\u00a0cm) (1910.29(g)(4)). For fixed ladders that extend more than 24 feet (7.3\u00a0m) above a lower level, 1910.28(b)(9) adds spacing rules. With a personal fall arrest system or ladder safety system, the ladder has rest platforms provided at maximum intervals of 150 feet (45.7\u00a0m). Ladder sections with a cage or well are offset from adjacent sections and have landing platforms provided at maximum intervals of 50 feet (15.2\u00a0m). Since November 19, 2018, a new fixed ladder over 24 feet needs a personal fall arrest system or a ladder safety system; a cage alone does not meet that duty.<\/p>\n<p>Surespan&#8217;s own recommendation is tighter: its SL sheet recommends landing platforms at 6m (approx. 19.7 ft) between platforms or landings. That is Surespan&#8217;s product guidance, not an OSHA figure.<\/p>\n<h2>How do you stop unauthorized climbing?<\/h2>\n<p>An external roof ladder can be climbed by anyone who reaches its foot. The SL sheet lists three answers:<\/p>\n<ul>\n<li><strong>Ladder guard:<\/strong> listed as an option for the SL, in lengths of 2m (LG2) and 2.5m (LG25), approx. 6.6 ft and 8.2 ft.<\/li>\n<li><strong>Security closure:<\/strong> a padlock closure for caged ladders.<\/li>\n<li><strong>Retractable lower section (SLC\/RS):<\/strong> the sheet says the SureSlide lower section can be released from the top of the ladder for escape from the roof, with operation from below possible.<\/li>\n<\/ul>\n<h2>What does Surespan&#8217;s SL ladder offer, and what should you check?<\/h2>\n<p>The SL is an aluminum fixed ladder for an angle of inclination of 75\u00b0-90\u00b0, supplied self color (unfinished) as standard, with polyester powder coating to any standard stocked RAL color as an option. The sheet is a UK data sheet and makes no reference to OSHA. Ask Surespan to confirm the rung spacing, clear width, clearances and rail extensions of the ladder offered for your project against 1910.23, and have your safety professional check the installed layout. See the <a href=\"https:\/\/surespancovers.com\/us\/product\/fixed-vertical-ladders\/\">fixed vertical ladders<\/a> page for the range.<\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>What is a walk-through ladder?<\/h3>\n<p>A fixed ladder whose side rails continue above the top and flare apart, so the climber walks through between them onto the roof. OSHA calls it a through ladder.<\/p>\n<h3>How high must a roof ladder extend above a parapet?<\/h3>\n<p>The side rails of through and side-step ladders extend at least 42 inches (1.1\u00a0m) above the access level. Where the parapet is continuous, the access level is the top of the parapet.<\/p>\n<h3>Does a roof access ladder need a cage?<\/h3>\n<p>Not under OSHA&#8217;s current rules for new ladders. For fixed ladders over 24 feet installed on or after November 19, 2018, the required protection is a personal fall arrest system or a ladder safety system. A cage can still be fitted, but it is not a ladder safety system.<\/p>\n<h3>How often do I need landing platforms?<\/h3>\n<p>Under 1910.28(b)(9), at maximum intervals of 150 feet for rest platforms on a ladder with a ladder safety system or personal fall arrest system, and 50 feet for landing platforms on caged or well sections. Surespan recommends platforms at 6m on its own ladders.<\/p>\n<p>Drawings are in the <a href=\"https:\/\/surespancovers.com\/us\/resource-centre\/ladder-resources\/\">ladder resources<\/a>, and the full <a href=\"https:\/\/surespancovers.com\/us\/product-category\/ladders\/\">access ladder range<\/a> includes companionway and retractable ladders. To discuss a layout, send the climb height and a photo or section of the roof edge through the <a href=\"https:\/\/surespancovers.com\/us\/contact-us\/\">Surespan contact page<\/a>.<\/p>\n<h2>Sources<\/h2>\n<ul>\n<li>Surespan data sheet &#8220;Standard Ladder Access SL&#8221; (fixed vertical ladder), undated: arrangements, ladder guard, security closure, retractable lower section, landing platform recommendation, angle, finish. Product page: <a href=\"https:\/\/surespancovers.com\/us\/product\/fixed-vertical-ladders\/\">Fixed Vertical Ladders<\/a>.<\/li>\n<li>OSHA 29 CFR 1910.23 (ladders), paragraph (d), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.23\" target=\"_blank\" rel=\"noopener\">osha.gov<\/a>.<\/li>\n<li>OSHA 29 CFR 1910.28 (duty to have fall protection), paragraph (b)(9), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.28\" target=\"_blank\" rel=\"noopener\">osha.gov<\/a>.<\/li>\n<li>OSHA 29 CFR 1910.29 (fall protection systems criteria), paragraph (g)(4), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.29\" target=\"_blank\" rel=\"noopener\">osha.gov<\/a>.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Which fixed roof access ladder layout fits your building: hatch, walk-through, side-step, parapet step-over or platforms, and what OSHA 1910.23 asks of each.<\/p>\n","protected":false},"author":6,"featured_media":48306,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_ayudawp_aiss_exclude":false,"_ayudawp_aiss_exclude_summary":false,"_ayudawp_aiss_summary":"A fixed roof access ladder reaches the roof in one of five layouts: up through a roof hatch from inside, over the roof edge as a walk-through ladder, beside the edge as a side-step ladder, over a parapet with a step-over platform, or in stages with landing platforms. OSHA sets three things at the top:. the side rails extend at least 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder (d)(4);. the rungs are omitted from the extension, and the rails flare to give not less than 24 inches (61cm) and not more than 30 inches (76 cm) of clearance, or up to 36 inches (91 cm) where a ladder safety system is provided (d)(5);. the step-across distance from the rung centerline to the nearest edge of the structure is not less than 7 inches (18 cm) and not more than 12 inches (30 cm) (d)(12)(i). For parapet ladders, OSHA defines the access level as \"the roof, if the parapet is cut to permit passage through the parapet\" or \"the top of the parapet, if the parapet is continuous.\" With a continuous parapet, the rails therefore extend 42 inches above the parapet top, and the climber needs a safe way down onto the roof on the other side.","_ayudawp_aiss_summary_provider":"extractive","_ayudawp_aiss_summary_hash":"e5d10adcc585015f0ffb461af94f8ac3f0e2a163","footnotes":""},"categories":[525],"tags":[],"country":[],"product-supplied":[],"class_list":["post-50043","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles"],"acf":[],"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts\/50043","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/comments?post=50043"}],"version-history":[{"count":0,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts\/50043\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/media\/48306"}],"wp:attachment":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/media?parent=50043"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/categories?post=50043"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/tags?post=50043"},{"taxonomy":"country","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/country?post=50043"},{"taxonomy":"product-supplied","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/product-supplied?post=50043"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}