{"id":50051,"date":"2026-06-09T11:22:34","date_gmt":"2026-06-09T10:22:34","guid":{"rendered":"https:\/\/surespancovers.com\/us\/ships-ladder-angles-osha\/"},"modified":"2026-06-09T11:22:34","modified_gmt":"2026-06-09T10:22:34","slug":"ships-ladder-angles-osha","status":"publish","type":"post","link":"https:\/\/surespancovers.com\/us\/ships-ladder-angles-osha\/","title":{"rendered":"What Is a Ship&#8217;s Ladder? Angles, Treads and the OSHA Ship Stair Rules"},"content":{"rendered":"<p>A ship&#8217;s ladder, also called a ship stair or companionway ladder, is a steep stair with treads, handrails and open risers. It sits between a standard stair and a vertical ladder, and it is used where a mezzanine, plant room or roof hatch needs regular access but there is no room for a full stair. In US workplaces, OSHA&#8217;s general industry rule 29 CFR 1910.25(e) sets ship stairs at a slope of 50 to 70 degrees from the horizontal, with a rise of 6.5 to 12 inches, treads at least 4 inches deep and at least 18 inches wide.<\/p>\n<p>This article covers the federal OSHA rule for general industry and Surespan&#8217;s SHP companionway ladder. State and local building codes can set their own limits for ship&#8217;s ladders, so check the code your project is permitted under as well.<\/p>\n<h2>How does OSHA define a ship stair?<\/h2>\n<p>OSHA&#8217;s walking-working surfaces subpart applies to all general industry workplaces (29 CFR 1910.21(a)). Its definitions treat a ship&#8217;s ladder as a stair, not a ladder. A ship stair (ship ladder) &#8220;means a stairway that is equipped with treads, stair rails, and open risers, and has a slope that is between 50 and 70 degrees from the horizontal.&#8221; The same section says a fixed ladder does not include ship stairs.<\/p>\n<p>That matters for the rules that apply. A ship stair falls under the stairway section, 29 CFR 1910.25, and not under the fixed ladder section, 1910.23.<\/p>\n<h2>What does 29 CFR 1910.25(e) require for ship stairs?<\/h2>\n<p>In addition to the general stairway rules in 1910.25(b), the employer must ensure ship stairs:<\/p>\n<ul>\n<li>are installed at a slope of 50 to 70 degrees from the horizontal, (e)(1);<\/li>\n<li>have open risers with a vertical rise between tread surfaces of 6.5 to 12 inches (17 to 30\u00a0cm), (e)(2);<\/li>\n<li>have a minimum tread depth of 4 inches (10\u00a0cm), (e)(3);<\/li>\n<li>have a minimum tread width of 18 inches (46\u00a0cm), (e)(4).<\/li>\n<\/ul>\n<p>The general rules that also apply include uniform riser heights and tread depths between landings, 1910.25(b)(3), and a vertical clearance above any stair tread of at least 6 feet, 8 inches (203\u00a0cm) to any overhead obstruction, 1910.25(b)(2). Handrails, stair rail systems and guardrail systems are provided in accordance with 1910.28, 1910.25(b)(1).<\/p>\n<h2>When may you use a ship&#8217;s ladder instead of a stair?<\/h2>\n<p>OSHA limits the choice. Under 1910.25(b)(8), spiral, ship or alternating tread-type stairs are used only when the employer can demonstrate that it is not feasible to provide standard stairs. Typical cases are a plant room, a roof hatch over a corridor or a mezzanine where the footprint of a standard stair will not fit. Standard stairs, for comparison, are installed at angles between 30 to 50 degrees from the horizontal, 1910.25(c)(1).<\/p>\n<table class=\"mtr-table mtr-thead-th\">\n<thead>\n<tr>\n<th data-mtr-content=\"Access type (OSHA term)\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Access type (OSHA term)<\/div><\/th>\n<th data-mtr-content=\"Slope in the OSHA text\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Slope in the OSHA text<\/div><\/th>\n<th data-mtr-content=\"Section\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Section<\/div><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-mtr-content=\"Access type (OSHA term)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Standard stairs<\/div><\/td>\n<td data-mtr-content=\"Slope in the OSHA text\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">30 to 50 degrees<\/div><\/td>\n<td data-mtr-content=\"Section\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.25(c)(1)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Access type (OSHA term)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Ship stairs<\/div><\/td>\n<td data-mtr-content=\"Slope in the OSHA text\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">50 to 70 degrees<\/div><\/td>\n<td data-mtr-content=\"Section\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.25(e)(1)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Access type (OSHA term)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Alternating tread-type stairs<\/div><\/td>\n<td data-mtr-content=\"Slope in the OSHA text\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">50 to 70 degrees<\/div><\/td>\n<td data-mtr-content=\"Section\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.25(f)(1)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Access type (OSHA term)\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Fixed ladders<\/div><\/td>\n<td data-mtr-content=\"Slope in the OSHA text\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">a pitch greater than 90 degrees from the horizontal is not used<\/div><\/td>\n<td data-mtr-content=\"Section\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1910.23(d)(11)<\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>What angle range does the SHP companionway ladder use?<\/h2>\n<p>Surespan&#8217;s SHP companionway ladder is made in aluminum with a rake of 65\u00b0-75\u00b0. Its data sheet carries its own angle chart, which divides the slopes like this: 30\u00b0 &#8211; 50\u00b0 for staircases, 50\u00b0 &#8211; 65\u00b0 marked as a danger range to be avoided, 65\u00b0 &#8211; 75\u00b0 for SHP ship ladders and 75\u00b0 &#8211; 90\u00b0 for fixed access ladders.<\/p>\n<p>Set side by side, the two schemes do not line up. The SHP range runs from 65\u00b0 to 75\u00b0, while OSHA&#8217;s ship stair limit stops at 70 degrees. The SHP chart also marks 50\u00b0 to 65\u00b0 as a range to avoid, which sits inside OSHA&#8217;s ship stair range. If your ladder has to be treated as an OSHA ship stair, the installed angle must fall within 50 to 70 degrees: state the required angle on your drawings and have it confirmed at the design stage. The SHP figures below are Surespan&#8217;s own design figures, not a statement that the ladder meets OSHA.<\/p>\n<h2>What does the SHP data sheet give?<\/h2>\n<table class=\"mtr-table mtr-thead-th\">\n<thead>\n<tr>\n<th data-mtr-content=\"Item\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">Item<\/div><\/th>\n<th data-mtr-content=\"SHP data sheet\" class=\"mtr-th-tag\"><div class=\"mtr-cell-content\">SHP data sheet<\/div><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Rake<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">65\u00b0-75\u00b0<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Maximum rise of one ladder<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">3000\u00a0mm (118.1 in)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Handrail height above the floor slab at the top<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">1100\u00a0mm min. (43.3 in)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Minimum dimension between handrails<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">540\u00a0mm (21.3 in)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Maximum gap, wall to tread<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">50\u00a0mm (2.0 in)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Width at the standard base fixing<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">450-550\u00a0mm (17.7 to 21.7 in)<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Handrails<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Single line handrail each side, continuous with the platform top handrail<\/div><\/td>\n<\/tr>\n<tr>\n<td data-mtr-content=\"Item\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Finish<\/div><\/td>\n<td data-mtr-content=\"SHP data sheet\" class=\"mtr-td-tag\"><div class=\"mtr-cell-content\">Unpainted (self color) as standard, polyester powder coating to a standard stocked RAL color as an option<\/div><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The sheet names BS EN ISO 14122-1:2016 as the design basis for all Surespan access ladders. That is a European and international standard. It is not an OSHA rule or a US building code requirement, and it does not replace the checks above.<\/p>\n<h2>How does a ship&#8217;s ladder work with a roof hatch?<\/h2>\n<p>A ship&#8217;s ladder needs a longer opening than a vertical ladder, because the user climbs at an angle and needs headroom over the upper treads. Surespan&#8217;s guidance is that with a roof hatch the minimum structural opening is generally 1500 x 750\u00a0mm (59.1 x 29.5 in), but this varies with the height of the ladder and the depth of the ceiling, if there is one. The SHP sheet adds that the ladder can be designed and supplied together with a top opening roof hatch with a side door. See the <a href=\"https:\/\/surespancovers.com\/us\/product-category\/roof-hatches\/\">roof hatch range<\/a> for the hatch itself.<\/p>\n<p>Where the climb is short, the space tight and the access occasional, a fixed vertical ladder or a retractable ladder may be the better fit, and a ship&#8217;s ladder is not a substitute for a standard stair where one can be provided. See the full <a href=\"https:\/\/surespancovers.com\/us\/product-category\/ladders\/\">access ladder range<\/a> to compare.<\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>Is a ship&#8217;s ladder a ladder or a stair under OSHA?<\/h3>\n<p>A stair. 29 CFR 1910.21 defines a ship stair (ship ladder) as a stairway with treads, stair rails and open risers at 50 to 70 degrees, and excludes ship stairs from the definition of a fixed ladder. The stairway rules of 1910.25 apply.<\/p>\n<h3>What is the maximum angle for a ship&#8217;s ladder under OSHA?<\/h3>\n<p>70 degrees from the horizontal, under 1910.25(e)(1). The minimum is 50 degrees. Fixed ladders have their own rules in 1910.23, including rung spacing and clear width.<\/p>\n<h3>What tread size does OSHA require on ship stairs?<\/h3>\n<p>A minimum tread depth of 4 inches (10\u00a0cm) and a minimum tread width of 18 inches (46\u00a0cm), with open risers and a rise of 6.5 to 12 inches (17 to 30\u00a0cm) between tread surfaces.<\/p>\n<h3>Can I install a ship&#8217;s ladder where a standard stair would fit?<\/h3>\n<p>Not in a workplace covered by OSHA general industry rules. 1910.25(b)(8) allows ship stairs only when the employer can demonstrate that it is not feasible to provide standard stairs.<\/p>\n<h3>Does the SHP ladder angle range match OSHA?<\/h3>\n<p>Not fully. The SHP sheet gives 65\u00b0-75\u00b0, and OSHA ship stairs run from 50 to 70 degrees. Specify the angle you need on the drawings and confirm it before manufacture.<\/p>\n<p>To discuss a ship&#8217;s ladder for your project, send the floor-to-floor height, the opening size and the required angle through the <a href=\"https:\/\/surespancovers.com\/us\/contact-us\/\">Surespan contact page<\/a>. Drawings and data sheets are in the <a href=\"https:\/\/surespancovers.com\/us\/resource-centre\/ladder-resources\/\">ladder resources<\/a>.<\/p>\n<h2>Sources<\/h2>\n<ul>\n<li>Surespan data sheet &#8220;Ships Type Access Ladder SHP&#8221; (Ships Companionway Ladder), undated: rake, rise, handrail and base figures, angle chart, design basis. Product page: <a href=\"https:\/\/surespancovers.com\/us\/product\/companionway-ladders\/\">Companionway Ladders<\/a>.<\/li>\n<li>OSHA 29 CFR 1910.21 (scope and definitions), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.21\" target=\"_blank\" rel=\"noopener\">osha.gov<\/a>.<\/li>\n<li>OSHA 29 CFR 1910.23 (ladders), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.23\" target=\"_blank\" rel=\"noopener\">osha.gov<\/a>.<\/li>\n<li>OSHA 29 CFR 1910.25 (stairways), <a href=\"https:\/\/www.osha.gov\/laws-regs\/regulations\/standardnumber\/1910\/1910.25\" target=\"_blank\" rel=\"noopener\">osha.gov<\/a>.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>What a ship&#8217;s ladder is, the slope, rise and tread rules OSHA sets for ship stairs, and how a companionway ladder&#8217;s angle range compares.<\/p>\n","protected":false},"author":2,"featured_media":30159,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_ayudawp_aiss_exclude":false,"_ayudawp_aiss_exclude_summary":false,"_ayudawp_aiss_summary":"A ship's ladder, also called a ship stair or companionway ladder, is a steep stair with treads, handrails and open risers. A ship stair (ship ladder) \"means a stairway that is equipped with treads, stair rails, and open risers, and has a slope that is between 50 and 70 degrees from the horizontal.\" The same section says a fixed ladder does not include ship stairs. A stair. 29 CFR 1910.21 defines a ship stair (ship ladder) as a stairway with treads, stair rails and open risers at 50 to 70 degrees, and excludes ship stairs from the definition of a fixed ladder.","_ayudawp_aiss_summary_provider":"extractive","_ayudawp_aiss_summary_hash":"fe743ef0580250b9dbbe1d64f3f4d8941777ea56","footnotes":""},"categories":[525],"tags":[],"country":[],"product-supplied":[],"class_list":["post-50051","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles"],"acf":[],"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts\/50051","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/comments?post=50051"}],"version-history":[{"count":0,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/posts\/50051\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/media\/30159"}],"wp:attachment":[{"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/media?parent=50051"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/categories?post=50051"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/tags?post=50051"},{"taxonomy":"country","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/country?post=50051"},{"taxonomy":"product-supplied","embeddable":true,"href":"https:\/\/surespancovers.com\/us\/wp-json\/wp\/v2\/product-supplied?post=50051"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}