To measure for a commercial retractable ladder, often called an attic ladder in the US, you need four things: the floor to ceiling height measured to the structure, the length and width of the structural (rough) opening, the depth of the void above the ceiling, and the floor space the ladder swings into when it is pulled down. On Surespan’s ZIP8, the floor to ceiling height sets the length of the structural opening, so that is the first figure to get right.
This guide is for contractors and architects coordinating ceiling and roof access in commercial buildings, not for attic ladders in homes.
Which ZIP ladder are you specifying?
ZIP is the name of Surespan’s range of commercial retractable ladders. Some people use “ZIP ladder” for any folding ladder, so name the model in your inquiry:
Model |
How it is specified |
What to confirm early |
|---|---|---|
Ladder first, then coordinated with the opening and any hatch or lining detail. |
Whether you need a separate access hatch or lining, and the structural and clear openings the access route needs. |
|
Made to order and supplied as a complete unit with casing and trap door. |
Structural opening, floor to ceiling height, void depth, and any backboard, handrail or operating options. |
What do you need to measure?
Measurement |
What it is |
Common mistake |
|---|---|---|
Structural opening length |
The length of the opening formed in the structure, used to size the unit. A minimum applies. |
Giving the lid size, or an “opening” with no label. |
Structural opening width |
The width of the opening formed in the structure. A minimum applies. |
Mixing up the structural opening and the clear opening. |
Floor to ceiling height |
The height range the ladder is made for. State the datum you measured from and to. |
Measuring to the suspended ceiling tiles instead of the structure above. |
Void depth |
The depth available above the ceiling line, with any obstructions. |
Finding duct or pipe clashes after installation has started. |
Casing height |
The height of the ladder’s casing. Confirm it if your ceiling build-up is not standard. |
Not checking how the casing meets the ceiling build-up. |
Backboard (optional) |
Height and width of an optional backboard for fixing and finishing. |
Leaving the backboard until late, when it clashes with the hatch or finishes. |
For ZIP8, allow for the casing being made slightly smaller than the structural opening. That is normal and gives installation tolerance.
Structural opening, clear opening or “trap”?
Three words get used for the same hole, and they are not the same:
- Structural opening: the opening formed in the structure by the builder, close to what US framers call the rough opening.
- Clear opening: the usable size you can pass through once the frame and linings are in.
- “Trap”: an informal word that can mean the lid, the lining or the hole. Avoid it on drawings.
Label every dimension on the drawing as structural or clear.
How much floor space does the ladder need?
A retractable ladder swings down in an arc and lands some distance from the casing. The ZIP8 data sheet gives two figures for each band of floor to ceiling height: the touch down point, measured on the floor from the casing side, and the operating space, the arc the ladder swings through. The casing is 240mm (9.4 in) deep as standard.
Floor to ceiling height, mm (in) |
Touch down point, mm (in) |
Operating space, mm (in) |
|---|---|---|
2200 to 2500 (86.6 to 98.4) |
1350 to 1200 (53.1 to 47.2) |
1450 (57.1) |
2500 to 2790 (98.4 to 109.8) |
1450 to 1300 (57.1 to 51.2) |
1550 (61.0) |
2791 to 3090 (109.9 to 121.7) |
1550 to 1440 (61.0 to 56.7) |
1650 (65.0) |
3091 to 3390 (121.7 to 133.5) |
1660 to 1540 (65.4 to 60.6) |
1770 (69.7) |
3391 to 3690 (133.5 to 145.3) |
1770 to 1640 (69.7 to 64.6) |
1890 (74.4) |
3691 to 3990 (145.3 to 157.1) |
1880 to 1740 (74.0 to 68.5) |
2010 (79.1) |
3991 to 4300 (157.1 to 169.3) |
1980 to 1830 (78.0 to 72.0) |
2030 (79.9) |
Check the corridor width, door swings and anything else in that zone, so the ladder can come down and be climbed without creating a pinch point.
What about suspended ceilings?
Where there is a drop ceiling, give two heights: the finished ceiling line, for the trap door position and finishes, and the height to the structural soffit (the underside of the slab), for fixing. A retractable ladder is fixed to the structure above, never to a suspended ceiling grid. In a deep ceiling zone, plan the liner and finishing detail early.
How do you check the void above the ceiling?
Mark up the void depth and anything in it: ductwork, cable trays, pipework, sprinklers and lighting can clash with the casing or the path the ladder swings through. Check the structural depth at the opening as well. Where the slab is much thicker than the casing or lining, the opening may need an extension or lining to bridge the build-up.
What does the ZIP8 data sheet state?
- Die cast aluminum alloy ladder with aluminum non-slip treads and an insulated wooden trapdoor.
- 62mm (2.4 in) insulated sandwich trapdoor, underside finished in white.
- Timber surround 19mm (0.7 in) thick and 240mm (9.4 in) high.
- Standard tread 350mm by 140mm depth (13.8 by 5.5 in); other sizes on request.
- Loading 200kg per tread (approx. 441 lb).
- Counterbalanced springs in the pivot bracket; spring latch locked with an operating pole.
- One side telescopic handrail; bespoke sizes available.
- Certified to EN14975, the European standard for loft (attic) ladders.
The ZIP 4 to ZIP 7 sheet gives a minimum aperture of 600 x 900 mm (23.6 x 35.4 in) for all four models and asks you to add 50mm (2.0 in) to the minimum aperture width to allow for the frame thickness of a ceiling door. It also says it is up to the customer to make sure the aperture is large enough. The models weigh 28kg (ZIP 4), 30kg (ZIP 5), 32kg (ZIP 6) and 34kg (ZIP 7), approx. 62, 66, 71 and 75 lb.
Is a retractable ladder the right choice?
A retractable ladder suits occasional access where the floor below must stay clear. It is not automatically right for frequent use or where people carry equipment. If the route is used regularly, or the swing zone is tight, a fixed vertical ladder or a companionway ladder may fit better.
If the opening is in a fire-rated ceiling or floor, confirm early whether the hatch needs a fire rating. Fire performance comes from the hatch specification and the installation detail, so do not assume a ladder and hatch combination carries a rating.
Frequently asked questions
What size opening does a commercial attic ladder need?
It depends on the model and the ceiling height. For ZIP 4 to ZIP 7 the minimum aperture is 600 x 900 mm (23.6 x 35.4 in). For ZIP8 the floor to ceiling height sets the length of the structural opening, so send the height first.
Do I measure to the ceiling tiles or the slab?
Both, where there is a suspended ceiling: the finished ceiling line and the structural soffit. The ladder fixes to the structure.
How far into the room does the ladder land?
On ZIP8, from 1350 to 1200 mm (53.1 to 47.2 in) for a 2200 to 2500 mm (86.6 to 98.4 in) floor to ceiling height, up to 1980 to 1830 mm (78.0 to 72.0 in) for 3991 to 4300 mm (157.1 to 169.3 in), measured on the floor from the casing side.
What should I send for a quote?
A marked-up drawing with the structural opening length and width, the floor to ceiling height and its datum, the void depth, whether the ceiling is suspended and the soffit height, any services in the way, the swing zone constraints, and whether the ladder is coordinated with an access hatch.
See the full access ladder range and the ladder resources. To ask for a coordinated ladder, or ladder and hatch, use the Surespan contact page.
Sources
- Surespan data sheet “ZIP8 Retractable Ladder” (ZIP8), REV 1.0, April 2021: material, trapdoor, lining, treads, loading, operation, EN14975, operating dimensions. Product page: ZIP8 Retractable Ladders.
- Surespan data sheet “ZIP4-7 Retractable Ladder” (ZIP 4 to ZIP 7), REV 2.0, June 2021: minimum aperture, weights. Product page: ZIP Retractable Ladders.