OSHA’s fixed ladder requirements are in 29 CFR 1910.23. For a fixed ladder in a general industry workplace, the rungs must be 10 to 14 inches (25 to 36 cm) apart between centerlines, with a clear width of at least 16 inches (41 cm), at least 7 inches (18 cm) of clearance behind the rungs, and side rails on through and side-step ladders that extend at least 42 inches (1.1 m) above the access level. Fall protection for fixed ladders that extend more than 24 feet (7.3 m) above a lower level is set separately, in 1910.28(b)(9).

This article covers the federal OSHA rules for general industry (29 CFR 1910, subpart D, which “applies to all general industry workplaces”). The building code adopted for your project and other rules can add their own requirements.

What counts as a fixed ladder?

OSHA defines a fixed ladder as “a ladder with rails or individual rungs that is permanently attached to a structure, building, or equipment.” Fixed ladders include individual-rung ladders, “but not ship stairs, step bolts, or manhole steps.” Two layouts matter at the top of the ladder:

  • a through ladder lets the climber step through the side rails at the top to reach a walking-working surface, such as a landing or roof;
  • a side-step ladder requires the climber to step sideways off the ladder to reach the walking-working surface.

Section 1910.23 covers all ladders, with two exceptions: a ladder used in emergency operations such as firefighting, rescue, and tactical law enforcement operations, or training for them, and a ladder designed into or an integral part of machines or equipment.

OSHA fixed ladder dimensions at a glance

Requirement
OSHA figure
Paragraph
Rung spacing, between centerlines
not less than 10 inches (25 cm) and not more than 14 inches (36 cm); other limits apply in elevator shafts and on telecommunication towers
1910.23(b)(2)
Minimum clear width of rungs
16 inches (41 cm), measured before installation of ladder safety systems
1910.23(b)(4)
Clearance behind the ladder
7 inches (18 cm) from rung centerline to the nearest permanent object; 4.5 inches (11 cm) for elevator pit ladders
1910.23(d)(2)
Side rail extension, through and side-step ladders
at least 42 inches (1.1 m) above the access level or landing platform
1910.23(d)(4)
Rail flare at a through ladder
not less than 24 inches (61cm) and not more than 30 inches (76 cm); maximum 36 inches (91 cm) with a ladder safety system
1910.23(d)(5)
Grab bars
extend 42 inches (1.1 m) above the access level or landing platforms
1910.23(d)(7)
Step-across distance
through ladders 7 inches (18 cm) to 12 inches (30 cm); side-step ladders 15 inches (38 cm) to 20 inches (51 cm)
1910.23(d)(12)
Side clearance, ladders without cages or wells
15 inches (38 cm) on each side of the centerline
1910.23(d)(13)(i)
Climbing-side clearance, ladders without cages or wells
30 inches (76 cm); 24 inches (61 cm) at unavoidable obstructions with deflector plates
1910.23(d)(13)(ii)
Pitch
no fixed ladder with a pitch greater than 90 degrees from the horizontal
1910.23(d)(11)
Platforms used with fixed ladders
a horizontal surface of at least 24 inches by 30 inches (61 cm by 76 cm)
1910.29(g)(4)

Paragraph (d)(1) adds the load rule in one line: fixed ladders are capable of supporting their maximum intended load. OSHA states the duty, not a test load, so ask the ladder maker how the ladder and its fixings were designed for that load.

How do the rail extension rules work at a roof edge or parapet?

The 42-inch extension is measured from the access level, and for parapet ladders OSHA defines that level two ways. The access level is the roof, if the parapet is cut to permit passage through the parapet, and the top of the parapet, if the parapet is continuous. A ladder that climbs over a continuous parapet therefore needs its side rails to extend 42 inches above the parapet top, not the roof.

At a through ladder the rungs are left out of the extension and the rails flare to give 24 to 30 inches of clearance between them, so the climber can walk through. At a side-step ladder the side rails, rungs and steps must be continuous in the extension. The step-across distance then sets how far the climber reaches: 7 to 12 inches to the edge of the structure for a through ladder, 15 to 20 inches to the access points of the platform edge for a side-step ladder. Layout options for roof ladders are worked through in a separate guide on walk-through, parapet and platform layouts.

What does OSHA say about a ladder that ends at a roof hatch?

When a fixed ladder terminates at a hatch, the hatch cover must open “with sufficient clearance to provide easy access to or from the ladder” and, if the hatch is counterbalanced, open “at least 70 degrees from horizontal” (1910.23(d)(9)). Check the hatch’s opening angle and the space above the top rung together, because a hatch that opens fully can still leave too little headroom for the last step. Surespan’s roof hatch range lists ladder arrangements for each hatch.

When does a fixed ladder need fall protection?

The dimensions above apply to every fixed ladder. Fall protection depends on height. Under 1910.28(b)(9), for fixed ladders that extend more than 24 feet (7.3 m) above a lower level, a ladder installed on and after November 19, 2018 must have a personal fall arrest system or a ladder safety system, and on and after November 18, 2036 all fixed ladders must. A cage or well alone is accepted only on ladders installed before November 19, 2018, and only until November 18, 2036, and OSHA’s definitions are blunt: “Cages and wells are not ladder safety systems.”

How does Surespan’s fixed ladder fit in?

Surespan’s fixed vertical ladder data sheet (SL) describes an aluminum ladder in six arrangements: the standard ladder (SL), with cage (SLC), with walk through (SL/WT), with cage and walk through (SLC/WT), with cage and retractable lower section (SLC/RS), and with walk through and parapet stepover platform (SL/PS, SLC/PS). Options include a ladder guard, landing platforms, a security closure, a retractable handhold and powder coating.

The SL sheet is a UK data sheet and makes no reference to OSHA. Before you specify, ask Surespan to confirm the rung spacing, clear width and clearances of the ladder offered for your project against each line of the table above, and have your safety professional check the installed layout. Several of the OSHA dimensions, such as the clearances, the rail extension and the step-across distance, also depend on where the ladder is fixed.

Frequently asked questions

What is the OSHA rung spacing for a fixed ladder?

Not less than 10 inches (25 cm) and not more than 14 inches (36 cm), measured between the centerlines of the rungs, under 1910.23(b)(2). The rungs must also be parallel, level, and uniformly spaced when the ladder is in position for use.

How wide must a fixed ladder be?

The rungs need a minimum clear width of 16 inches (41 cm), measured before any ladder safety system is installed, under 1910.23(b)(4). Ladders without cages or wells also need 15 inches (38 cm) of clear width on each side of the centerline to the nearest permanent object.

How far must the side rails extend above the roof?

At least 42 inches (1.1 m) above the top of the access level or landing platform, for through and side-step ladders. Where a ladder serves a continuous parapet, the access level is the top of the parapet.

Does OSHA still require a cage on a fixed ladder?

No. For fixed ladders that extend more than 24 feet above a lower level and were installed on or after November 19, 2018, the required protection is a personal fall arrest system or a ladder safety system. A cage may still be fitted, but it does not count as either.

Is a ship’s ladder a fixed ladder under OSHA?

Not if it is a ship stair. OSHA’s definition of a fixed ladder excludes ship stairs, and section 1910.25 on stairways covers ship stairs instead.

For ladder drawings, see the ladder resources and the access ladder range. To discuss a roof access ladder, send the climb height and the arrangement at the top through the Surespan contact page.

Sources

  • OSHA 29 CFR 1910.23 (ladders), paragraphs (a), (b) and (d), osha.gov.
  • OSHA 29 CFR 1910.28 (duty to have fall protection), paragraph (b)(9), osha.gov.
  • OSHA 29 CFR 1910.29 (fall protection systems criteria), paragraph (g)(4), osha.gov.