A skylight roof hatch is a glazed roof hatch: a hinged lid with a sealed glass unit, on an insulated curb, that lets daylight into the space below and opens fully so people can climb out onto the roof. An ordinary fixed skylight cannot do this job. A unit used for access needs a lid that opens wide and stays open, a lock, safety glass and a curb that is built for people passing through. On a US workplace roof, OSHA 29 CFR 1910.28(b)(3)(i) treats a skylight as a hole and requires protection from falling through any hole (including skylights) 4 feet or more above a lower level.
This guide covers glazed hatches for access. For how US and European skylight standards compare, see Comparing US and EU Standards for Skylights.
When does a skylight roof hatch make sense?
- A stair or landing at the top of a building that needs both daylight and a way onto the roof.
- A roof terrace on an apartment or house, where a solid hatch would leave the stair dark.
- A commercial roof where one opening is cheaper and neater than a skylight beside a hatch.
Where access is only for maintenance and there is no need for light, a solid insulated roof hatch is simpler.
What glazing does a roof access skylight need?
The glass is the lid, so it has to carry weather, resist impact and protect the people below. Surespan’s Boxed Glazed Roof Access hatch (BG) data sheet specifies a 35.5mm (1.4 in) sealed double glazed unit:
Layer |
BG data sheet |
|---|---|
Outer pane |
Pilkington 6mm (0.2 in) toughened K, polished all round |
Cavity |
20mm (0.8 in) warm edge silver spacer bar, argon filled |
Inner pane |
Pilkington 9.5mm (0.4 in) toughened and laminated |
Glazed unit U-value |
1.5 W/m²K |
The laminated inner pane is the important layer for safety: if the glass breaks, the interlayer holds the pieces together. The U-value is that of the sealed glazed unit, not of the complete hatch with its frame and curb.
The Aero Electric Roof Access Rooflight is a skylight that opens fully, so it doubles as an extra point of access to the roof. Its data sheet gives a laminated safety inner pane meeting Class 2 for non-fragility under the red book of the UK Advisory Committee for Roof Safety, with reference to CWCT TN65, 66 and 67. It also gives air permeability Class 4 to BS EN 1026:2016 and BS EN 12207:2000, and an acoustic value of RW = 39dB, by calculation only, to EN ISO 140-3. These are UK and European tests, not US ratings.
What hardware does it need?
The BG sheet gives:
- an aluminum frame and a double skinned aluminum lid;
- gas spring assisted opening, with electric operation available;
- a heavy duty stainless steel cab lock that, as standard, can only be opened from the inside, with other locking options on request;
- a frame 313mm (12.3 in) high as standard, with a purpose made flashing on the curb to take the roofing felt, which is supplied by others;
- a recommended installation pitch of 5° to stop water ponding on the glass.
Ask for a hold-open stay as well, so the lid cannot close on someone climbing through. Where a fixed ladder ends at a hatch, OSHA 29 CFR 1910.23(d)(9) says the hatch cover opens with sufficient clearance to provide easy access to or from the ladder, and opens at least 70 degrees from horizontal if the hatch is counterbalanced.
What does OSHA say about skylights on a workplace roof?
OSHA’s general industry rules count a skylight as a hole. 29 CFR 1910.28(b)(3)(i) says each employee is protected from falling through any hole (including skylights) that is 4 feet or more above a lower level by covers, guardrail systems, travel restraint systems or personal fall arrest systems. Where a cover is used, 1910.29(e) asks that it supports at least twice the maximum intended load and is secured to prevent accidental displacement.
A non-fragility class from a UK test is not one of those measures in OSHA’s text. Whether a glazed lid can serve as the cover, or whether a guardrail or screen is needed around the unit, is for the employer’s safety professional to decide. When the lid is open for access, the open hatch needs protecting as any roof hatch does.
Is a skylight roof hatch a smoke vent?
Not unless it is built and tested as one. A smoke vent opens automatically on a fire signal. Surespan makes a separate Glazed Smoke Vent for that job.
Frequently asked questions
Can any skylight be used as a roof hatch?
No. A fixed skylight has no opening lid, and many opening skylights only open partly for ventilation. For access you need a unit made to open fully, with a lock, a hold-open stay and safety glass.
Is the glass in a skylight roof hatch walkable?
Do not treat it as walkable. A non-fragility class describes how the glazing behaves if someone falls onto it, not a surface to walk on. Use a walk-on glass product where people must stand on glass.
Can a skylight roof hatch open electrically?
Yes. The BG sheet lists electric operation as an option to the standard gas springs, and the Aero unit is sold as an electric roof access rooflight.
Does a skylight roof hatch need a curb?
Yes. The BG hatch has a 313mm (12.3 in) frame as standard, flashed into the roof covering, and is best set at 5° so water runs off the glass.
See the full range of Glazed Hatches and the glazed hatch resources. To ask about a specification, use the Surespan contact page.
Sources
- Surespan data sheet “Boxed Glazed Roof Access BG”, October 2018: material, glazing, U-value, frame, locking, lifting, pitch. Range: Glazed Hatches.
- Data sheet “Aero-Access Rooflight”, October 2024: opening, inner pane non-fragility, air permeability, acoustic value. Product page: Aero Electric Roof Access Rooflight.
- OSHA 29 CFR 1910.28 (duty to have fall protection), 1910.29 (fall protection systems, covers) and 1910.23 (ladders), osha.gov 1910.28, osha.gov 1910.29, osha.gov 1910.23.