Rough Opening vs Clear Opening vs Overall Size: How to Measure a Roof Hatch

The three dimensions of a roof hatch, where each is measured, who uses it, and a checklist so the hatch you order fits the hole you framed.

A roof hatch has three different sizes, and mixing them up can leave you with a hatch that does not fit the hole or clashes with what is around it on the roof. The rough opening, also called the structural opening, is the framed hole in the roof deck. The clear opening is the free space people and equipment pass through once the hatch is installed. The overall size is the outside footprint of the curb, flange and cover on the roof.

Always state which of the three a number refers to, and check it against the manufacturer’s general arrangement (GA) drawing, the dimensioned shop drawing for the exact unit.

What do the three dimensions mean?

  • Rough opening (structural opening, SO): the builder’s opening, measured between the framing members, joists or headers. This is the hole you cut and frame in the roof.
  • Clear opening (CO): the usable pass-through, measured inside the hatch frame. It decides what fits through: a person with a tool bag, a fan motor, a replacement compressor.
  • Overall size: the external footprint, including frame, flange and cover. It is the size to check against parapets, equipment, walkways and guardrails on the roof.
  • Model size: the nominal size in the product code, for example a “1000 x 1000” hatch. It is a name, not a measurement: confirm which of the three dimensions it refers to.
Term
Where it is measured
Who uses it
Rough (structural) opening
Framing member to framing member, at the structural opening line
The contractor framing the hole
Clear opening
Inside of the hatch frame
The user: what people and equipment can pass
Overall size
Outside of the frame, flange or cover, as shown on the GA drawing
The architect: clash checks on the roof

How do the three relate on real data sheets?

The relationship changes from product to product, which is why the drawing matters more than the name. Three Surespan sheets show it:

  • Sliding roof hatch (SLHP): the drawing states “SO – 76.2mm (3″) = CLEAR OPENING”. The clear opening is the structural opening less 76.2 mm (3.0 in). The same drawing gives a 220 mm (8.7 in) curb height.
  • Fire rated roof hatch (SRHTB/FR): on the drawing for the 1000 x 1000 unit, the approximate clear opening is SO – 21 (21 mm, about 0.8 in, less than the structural opening) and the flanges measure SO + 298 (298 mm, about 11.7 in, more).
  • Retrofit roof hatch (SRHP/RF): the standard sizes table is headed “structural opening”, from 600 x 600 mm (23.6 x 23.6 in) up to 750 x 3300 mm (29.5 x 129.9 in).

So a 1000 x 1000 mm hatch (39.4 x 39.4 in) on one sheet and the same nominal size on another may not give the same clear opening. If you need a given clear opening for equipment, put that number in the specification and let the manufacturer size the structural opening from it.

Worked example: setting out a sliding hatch

  1. Decide the clear opening you need, from the largest item that must pass through.
  2. For the SLHP, add 76.2 mm (3.0 in) to that clear opening to get the structural opening, as the drawing defines it.
  3. Frame the rough opening to that structural opening, measured at the structure, not at the finishes.
  4. Take the overall size from the GA drawing and check it against parapets, rooftop equipment, walkways and any guardrail around the hatch.
  5. Check the open position too: a hinged cover swings up and back, and a sliding cover needs room to travel, so the space around the hatch must suit the cover type.

Specification and site checklist

  • Name the dimension. Write “structural opening” or “clear opening” next to every size on drawings, schedules and purchase orders.
  • Check the footprint. Confirm the overall size fits between parapets and equipment, not just that the hole is the right size.
  • Do not measure finishes. Measure the structural opening in the framing, steel or concrete, not the drywall lining or the curb finish.
  • Check orientation. Confirm the hinge side and the ladder position, so the cover does not create a trapping hazard for the user.
  • Check the code size. If your adopted building code sets a minimum roof access opening, compare it with the clear opening, and use a bespoke size where a standard one is too small. Bespoke sizes are available on the SLHP and fire rated sheets.

One limit of this guide: smoke vents add another measure, the vent’s free or aerodynamic area, which is a performance figure and not a size you can take with a tape. Use the vent’s data sheet for that, not the opening dimensions.

Frequently asked questions

Is the rough opening the same as the structural opening?

Yes, for a roof hatch the two terms describe the same thing: the framed hole in the roof structure. Surespan’s sheets say structural opening, abbreviated SO.

Is the hatch size the clear opening?

Not always. On the SLHP drawing the clear opening is the structural opening less 76.2 mm (3.0 in), while the retrofit sheet lists its sizes as structural openings. Check the GA drawing for the unit you specify.

How much bigger than the opening is the overall size?

It depends on the curb, flange and cover. On the fire rated hatch drawing the flanges are SO + 298. Take the figure from the GA drawing of your unit.

Which size do I give when I ask for a quote?

Give the clear opening you need and the structural opening you have, each labeled, plus the roof build-up and the ladder position.

See also the standard roof hatch, the roof hatch range and the guide to what goes into a roof hatch. GA drawings are in the roof hatch resources. To check a set-out with Surespan, use the contact page.

Sources

  • Surespan data sheet “Thermally Broken SLHP (Telescopic) Sliding Hatch”, REV 2.0, March 2022: clear opening and curb height on the drawing. Product page: Sliding Roof Hatch.
  • Surespan data sheet “Fire Rated Roof Hatch” (SRHTB/FR), March 2026 (revision mark 06/22): clear opening and flange dimensions on the drawing. Product page: Fire Rated Roof Hatch.
  • Surespan data sheet “Retrofit Roof Hatch” (SRHP/RF), undated: standard sizes by structural opening. Product page: Retrofit Roof Hatch.

Robert Fletcher

Rob leads Surespan’s global specification efforts, translating access requirements into permit-ready, code-compliant solutions across hatches, covers, ladders, vents, and skylights. He manages submittals and approvals to keep projects moving through permitting the first time.