What Is a Roof Hatch? Parts, Uses and Options for Commercial Roofs

What a commercial roof hatch is, its two main parts, what it is used for, how it is insulated and secured, and what to decide when you specify one.

A roof hatch, also called a roof access hatch, is a hinged or sliding insulated cover on a raised curb, built into a commercial roof so that people can reach the roof from inside the building. It is used for maintenance of rooftop equipment, roof inspections and, on residential buildings, access to roof terraces. On a workplace roof, OSHA’s fall protection rule 29 CFR 1910.28(b)(3)(v) sets how workers must be protected from falling through a hatchway.

This guide is about roof hatches for commercial, institutional and multifamily buildings, not the small vents and hatches sold for RVs.

What are the parts of a roof hatch?

A roof hatch has two main parts that work together:

  • The curb (called an upstand in the UK): the fixed frame that is fastened to the roof structure. It raises the opening above the roof surface to keep water out and gives the cover a solid seat. Good curbs are often insulated and may include a thermal break.
  • The cover (or lid): the part that opens. It is insulated, seals against the curb when closed and keeps the building secure.

On Surespan’s sliding roof hatch (SLHP), for example, the data sheet gives an aluminum cover and frame, a 50 mm (2.0 in) fully insulated curb and lid, corner welded and reinforced, a 220 mm (8.7 in) curb with an external curb liner, a 120 mm (4.7 in) fixing flange, an integral weathering lip and a double unbroken bubble and blade seal to the lid.

Why does a roof hatch need insulation?

When the hatch is closed, its curb and cover are part of the roof’s thermal envelope. A thin or uninsulated hatch is a cold spot in an otherwise insulated roof. How much heat a hatch loses depends on the insulation material, its thickness and whether the frame is thermally broken.

The SLHP sheet gives 50 mm polyisocyanurate (polyiso, PIR) insulation to 0.43 W/m²K. That is the U-value of the insulation in the lid and curb, not of the complete hatch. Non-combustible mineral wool insulation is a free-of-charge option on the same sheet. Ask for the whole-unit value if your energy model needs one.

What is a roof hatch used for?

Commercial and institutional buildings

On offices, factories, hospitals and schools, roof hatches are mainly installed for:

  • Maintenance and servicing of rooftop equipment such as HVAC units, solar panels, communications equipment and lightning protection.
  • Inspections of the roof membrane, drains and structure.

An internal hatch moves the access point indoors. Technicians use the building’s stairs to the top floor and make a short climb, often 2.5 to 3 m (about 8.2 to 9.8 ft), through the hatch, instead of a long external ladder. That makes it easier to carry tools and to keep unauthorized people off the roof.

Where equipment on the roof needs servicing, the mechanical code may require permanent access. ICC’s CodeNotes on the 2021 International Mechanical Code (IMC 306.5) explains that portable ladders are permitted where the climb is not more than 16 feet above grade, and that for climbs exceeding 16 feet a permanent fixed ladder or some other approved permanent means of access is required. Check the edition your jurisdiction has adopted.

Residential buildings

On apartment buildings and houses with flat roofs, a hatch often gives access to a roof terrace or garden. Glazed hatches are popular here because they let daylight into the stairwell or hallway below.

How is a roof hatch opened and secured?

  • Opening: most hinged hatches use gas springs so that one person can open the cover in a controlled way. Larger or heavier hatches can be opened electrically. The SLHP sliding hatch is available with manual or electric opening, and Surespan’s double leaf hatch (SRHP/DL) uses gas spring assisted opening.
  • Opening angle: a wide opening angle, for example up to 85°, makes passing through easier and safer. Where a fixed ladder ends at a hatch, OSHA 1910.23(d)(9) says the hatch cover opens with sufficient clearance to provide easy access to or from the ladder, and opens at least 70 degrees from horizontal if the hatch is counterbalanced.
  • Locking: the SLHP sheet lists a stainless steel slam latch (LO1), an internal hasp and staple for a padlock (LO2) and an external padlockable handle (LO4) as standard, with European deadlock options LO6 (internal thumb turn, external key) and LO7 (key inside and outside).
  • Hold-open stay: a safety stay holds the cover open so it cannot close on the user.

What options should you decide on?

Decision
Options to consider
Size
Standard sizes or a custom size. The SLHP sheet lists standard sizes from 600 x 600 mm (23.6 x 23.6 in) to 1200 x 1200 mm (47.2 x 47.2 in), and bespoke sizes are available.
Hinged or sliding
A hinged cover, single or double leaf, or a sliding cover where there is no room for a cover to swing open.
Cover type
Solid insulated cover, or glazed for daylight.
Material
Aluminum for most roofs. Stainless steel, such as grades SS304 or SS316, where corrosion resistance matters in harsh environments.
Fire rating
A fire rated roof hatch where the roof is part of a fire separation (see below).
Safety accessories
The SLHP sheet lists a fixed handhold, the SureGuard handrail and a safety grid.
Ladder
Fixed vertical ladder, retractable ladder or companionway (ship’s) ladder under the hatch.

The double leaf roof hatch (SRHP/DL) suits a larger opening. Its sheet gives a 300 mm (11.8 in) curb with 75 mm (3.0 in) insulation and an acoustic rating option of up to 45 dB.

Surespan’s fire rated roof hatch (SRHTB/FR) is offered with integrity for 60/90/120/240 minutes, with the test standard printed on its drawings as EN1634-1:2014. The sheet gives integrity only: ask for the classification report, the fire direction and the tested size before you rely on it for a rated roof.

Is a roof hatch a fire exit?

Do not assume so. A hatch is designed for access. Whether a roof opening may form part of an escape route is a question for the building code and the fire engineer on your project, not for the hatch maker. Where a hatch and smoke ventilation are both needed, see Surespan’s smoke vent with access.

How do you protect people around an open hatch?

For workplaces, OSHA 29 CFR 1910.28(b)(3)(v) says each employee is protected from falling through a hatchway and chute-floor hole by a hinged floor-hole cover with a fixed guardrail system that leaves only one exposed side, by a removable guardrail system on not more than two sides with a fixed guardrail on the other exposed sides, or by a guardrail system or travel restraint system when material is passed through.

Frequently asked questions

What is the difference between a roof hatch and a skylight?

A skylight is designed to let in light and is not meant to be walked through. A roof hatch is designed for people to pass through, with a curb, an opening cover, locks and a hold-open stay.

Does a commercial building need a roof hatch?

Not always, but where equipment on the roof needs service and the climb is more than 16 feet, the 2021 IMC as explained by ICC requires a permanent fixed ladder or other approved permanent means of access. An internal hatch with a fixed ladder or ship’s ladder is one way to provide it. Your adopted code decides.

What size should a roof hatch be?

Large enough for the people and the largest piece of equipment that must pass through, and as your adopted building code requires. Surespan’s roof hatch range covers standard sizes and custom sizes.

Can a roof hatch be insulated to a better value?

Thicker insulation and a thermal break improve it. Compare the insulation values on each data sheet and ask for the whole-unit value if your model needs it.

For the product side of choosing a hatch, read How to choose the right roof hatch and A roof hatch is not just a square box. To ask about a specification, use the Surespan contact page.

Sources

  • Surespan data sheet “Thermally Broken SLHP (Telescopic) Sliding Hatch”, REV 2.0, March 2022: construction, insulation, locks, sizes, accessories. Product page: Sliding Roof Hatch.
  • Surespan data sheet “Double Door Roof Hatch SRHP/DL”, July 2022: curb, insulation thickness, opening, acoustic option. Product page: Double Leaf Roof Hatch.
  • Surespan data sheet “Fire Rated Roof Hatch” (SRHTB/FR), March 2026 (revision mark 06/22): integrity durations and test standard. Product page: Fire Rated Roof Hatch.
  • OSHA 29 CFR 1910.28 (duty to have fall protection), osha.gov, and 29 CFR 1910.23 (ladders), osha.gov.
  • ICC, CodeNotes: Worker Safety on Roofs and Elevated Surfaces (2021 IMC), iccsafe.org.
  • The full range: Roof Hatches and the Standard Roof Hatch.

Robert Fletcher

Rob leads Surespan’s global specification efforts, translating access requirements into permit-ready, code-compliant solutions across hatches, covers, ladders, vents, and skylights. He manages submittals and approvals to keep projects moving through permitting the first time.