Roof Hatch Ladders: Fixed, Ship’s or Retractable?

The three ladders that go under a commercial roof hatch, what OSHA 1910.23 and 1910.25 ask of fixed ladders and ship stairs, and how to choose.

Three kinds of ladder go under a commercial roof hatch: a fixed vertical ladder, a ship’s ladder (a steep stair with treads and handrails) and a retractable ladder that folds up into the ceiling. In US workplaces, OSHA’s general industry rules set the dimensions: 29 CFR 1910.23 for fixed ladders, with rungs 10 to 14 inches apart and a clear width of at least 16 inches, and 29 CFR 1910.25(e) for ship stairs, at a slope of 50 to 70 degrees from the horizontal. The right choice depends on how often people go up, what they carry and how much floor space there is below the hatch.

How do the three options compare?

Fixed vertical ladder
Ship’s ladder
Retractable ladder
OSHA treats it as
A fixed ladder, 1910.23
A ship stair, 1910.25(e)
Check with your safety professional
Floor space below
Least
Most: the climb runs at an angle
None when stowed; landing space when in use
Carrying tools
Hard: both hands on the ladder
Easiest of the three, with a handrail each side
Light items only
Typical use
Regular maintenance access; over 24 feet, with a ladder safety system or personal fall arrest system
Frequent access where a standard stair will not fit
Occasional access where the floor below must stay clear
Surespan product
ZIP Retractable Ladders (ZIP 4 to ZIP 7) and ZIP8

The double leaf roof hatch sheet (SRHP/DL) shows all three as ladder arrangements for the hatch: a ZIP, a vertical and a companionway ladder.

What does OSHA ask of a fixed ladder under a roof hatch?

OSHA’s walking-working surfaces subpart applies to all general industry workplaces. For fixed ladders, 29 CFR 1910.23 includes these points:

  • rungs, steps and cleats are spaced not less than 10 inches and not more than 14 inches apart, measured between centerlines, (b)(2);
  • a minimum clear width of 16 inches for fixed ladders, measured before installation of ladder safety systems, (b)(4);
  • a minimum perpendicular distance of 7 inches from the rung centerline to the nearest permanent object behind the ladder, (d)(2);
  • where there is no cage or well, a minimum perpendicular distance of 30 inches from the rung centerline to the nearest object on the climbing side, (d)(13)(ii);
  • where a fixed ladder terminates at a hatch, the hatch cover opens with sufficient clearance to provide easy access to or from the ladder, and opens at least 70 degrees from horizontal if the hatch is counterbalanced, (d)(9).

Height changes the fall protection. Under 29 CFR 1910.28(b)(9)(i), a fixed ladder that extends more than 24 feet above a lower level and was installed on and after November 19, 2018, is equipped with a personal fall arrest system or a ladder safety system. On and after November 18, 2036, all fixed ladders over 24 feet are. OSHA’s definitions add that cages and wells are not ladder safety systems.

Surespan’s SL range is made in aluminum with serrated rungs and 48.3mm (1.9 in) tube stringers. The sheet lists a plain ladder (SL), a caged ladder (SLC), walk-through versions (SL/WT and SLC/WT) and a caged ladder with a retractable lower section (SLC/RS), with options for a ladder guard, landing platforms, a security closure and a retractable hand hold. A cage is a choice the project may still want, but it does not replace the ladder safety system or personal fall arrest system OSHA asks for above 24 feet. Ask for the rung spacing and clear width of the ladder you are offered, and check them against 1910.23 before you order.

What does OSHA ask of a ship’s ladder?

OSHA calls it a ship stair: a stairway that is equipped with treads, stair rails and open risers, and has a slope between 50 and 70 degrees from the horizontal. OSHA’s definition of a fixed ladder excludes ship stairs. 29 CFR 1910.25(e) asks for:

  • a slope of 50 to 70 degrees from the horizontal;
  • open risers with a vertical rise between tread surfaces of 6.5 to 12 inches;
  • a minimum tread depth of 4 inches;
  • a minimum tread width of 18 inches.

There is a condition on using one at all. Under 1910.25(b)(8), spiral, ship or alternating tread-type stairs are used only when the employer can demonstrate that it is not feasible to provide standard stairs.

Surespan’s SHP companionway ladder is made in aluminum with a single line handrail each side, continuous with the platform top handrail, and a maximum rise of 3000mm (118.1 in) for one ladder. The sheet says it can be supplied together with a top opening roof hatch with a side door. State the installed angle you need on the drawings, and confirm it against 1910.25(e) at the design stage.

When is a retractable ladder the right choice?

A retractable ladder (US readers often say attic ladder) folds into a frame in the ceiling under the hatch. It suits occasional access, such as an inspection a few times a year, where the room below has to stay clear. It is the least suitable of the three for carrying tools or for frequent use.

Surespan’s ZIP ladders are die cast aluminum alloy with aluminum non-slip treads and counterbalanced springs. Both the ZIP 4 to ZIP 7 sheet and the ZIP8 sheet state certification to EN14975, the European standard for loft (attic) ladders. The ZIP8 sheet gives a maximum loading of 200kg per tread (approx. 441 lb) and a one side telescopic handrail, and the ZIP 4 to ZIP 7 sheet gives a minimum aperture of 600 x 900 mm (23.6 x 35.4 in) for all four models. EN14975 is a European standard, not an OSHA or US building code requirement.

One limit to know: where rooftop equipment needs service and the climb is more than 16 feet, ICC’s CodeNotes on the 2021 International Mechanical Code (IMC 306.5) says a permanent fixed ladder attached to the building or some other approved permanent means of access is required. Check with your code official whether a retractable ladder is accepted for that purpose before you specify one.

How do you choose?

  1. Count the trips: occasional inspection points to a retractable ladder, regular maintenance to a fixed ladder, frequent access with tools to a ship’s ladder.
  2. Measure the climb from floor to roof surface. More than 24 feet on a fixed ladder brings in OSHA’s ladder safety system or personal fall arrest system.
  3. Check the floor space below the hatch. A ship’s ladder needs the most, a retractable ladder none when it is stowed.
  4. Check what has to pass through: a ship’s ladder needs a longer hatch opening than a vertical ladder.
  5. Plan the top: the hatch cover’s opening angle, a handhold at the exit and, on a workplace roof, protection around the open hatch.

Frequently asked questions

What is the OSHA rung spacing for a roof hatch ladder?

Not less than 10 inches and not more than 14 inches apart, measured between the centerlines of the rungs, under 1910.23(b)(2), with a clear width of at least 16 inches for fixed ladders under 1910.23(b)(4).

Does a roof hatch ladder need a cage?

OSHA does not require one. For fixed ladders over 24 feet installed on and after November 19, 2018, it asks for a personal fall arrest system or a ladder safety system, and from November 18, 2036 for all fixed ladders over 24 feet. Cages and wells are not ladder safety systems.

Can a ship’s ladder go under a roof hatch?

Yes, where the opening is long enough and there is floor space for it. In a workplace it must meet 1910.25(e), and it may be used only when a standard stair is not feasible.

Is a retractable ladder allowed for commercial roof access?

It depends on the climb and the code your jurisdiction has adopted. For rooftop equipment above 16 feet, the IMC as ICC explains it asks for a permanent fixed ladder or other approved permanent means of access.

See the full access ladder range and the roof hatch range, including the Standard Roof Hatch. To ask about a hatch and ladder together, use the Surespan contact page.

Sources

  • Surespan data sheet “Standard Fixed Vertical Ladder” (SL), undated: models, material, stringers, options. Product page: Fixed Vertical Ladders.
  • Surespan data sheet “SHP Companionway Ladder” (SHP), undated: material, handrails, maximum rise, roof hatch with side door. Product page: Companionway Ladders.
  • Surespan data sheet “ZIP8 Retractable Ladder” (ZIP8), REV 1.0, April 2021: material, loading, handrail, EN14975. Product page: ZIP8 Retractable Ladders.
  • Surespan data sheet “ZIP4-7 Retractable Ladder” (ZIP 4 to ZIP 7), REV 2.0, June 2021: minimum aperture, EN14975. Product page: ZIP Retractable Ladders.
  • Surespan data sheet “Double Door Roof Hatch SRHP/DL”, July 2022: ladder arrangements. Product page: Double Leaf Roof Hatch.
  • OSHA 29 CFR 1910.21 (scope and definitions), 1910.23 (ladders), 1910.25 (stairways) and 1910.28 (duty to have fall protection), osha.gov 1910.23, osha.gov 1910.25, osha.gov 1910.28, osha.gov 1910.21.
  • ICC, CodeNotes: Worker Safety on Roofs and Elevated Surfaces (2021 IMC), iccsafe.org.

Robert Fletcher

Rob leads Surespan’s global specification efforts, translating access requirements into permit-ready, code-compliant solutions across hatches, covers, ladders, vents, and skylights. He manages submittals and approvals to keep projects moving through permitting the first time.